Plasma injection with helicon sources
Source abstract
Abstract
An exhaustive set of measurements has been made to find the optimum conditions for plasma injection into a processing chamber using small helicon sources with low magnetic fields B. It is found that the plasma density decreases, rather than increases, with B, as in normal helicon discharges. The design of the field coil and flange caused this effect; with a different design, normal operation was obtained. This experiment provides data on the area coverage of individual helicon discharges for the design of large-area, distributed plasma sources.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Plasma Diagnostics and Applications · Electrohydrodynamics and Fluid Dynamics · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Electrical Engineering Department, University of California, Los Angeles, Los Angeles, California 90095-1594
References (6)
Show source-provided references
1. J. Vac. Sci. Technol. A · 1997 · 15 · 288510.1116/1.580844 ↗
2. Plasma Phys. Controlled Fusion · 1997 · 39 · A41110.1088/0741-3335/39/5A/038 ↗
3. J. Vac. Sci. Technol. A · 1992 · 10 · 138910.1116/1.578256 ↗
4. Plasma Sources Sci. Technol. · 1998 · 7 · 6110.1088/0963-0252/7/1/009 ↗
5. Phys. Plasmas · 1998 · 5 · 123910.1063/1.872782 ↗
6. Plasma Sources Sci. Technol. · 1996 · 5 · 4310.1088/0963-0252/5/1/006 ↗