journal article·2019-05-01

Nanocrystalline tin oxide coatings on etched optical fiber Bragg grating for hydrogen sulfide detection

Bruno Rente, Alexandre Mello, Regina Allil, Marcelo M. Werneck, Sergio S. Camargo

Publisher page

Abstract

Hydrogen sulfide is a toxic and explosive gas commonly present in human industrial activities. Thus, it is imperative to efficiently measure this gas while also avoiding risks of creating sparks or heating. The aim of the present work is to develop and characterize a detection method capable of detecting hydrogen sulfide using the fiber Bragg grating interrogation technique. The method includes etching of the fiber cladding in the vicinity of the grating and pulsed laser deposition of tin oxide thin films as a sensitive layer that will be responsible for the Bragg wavelength shift when in contact with the gas. As shown by XPS analysis, the sensor response reaches a maximum when films exhibit a high concentration of oxygen vacancies. Results show resolution in the ppm range for hydrogen sulfide and fast recovery time, indicating that this can be a novel method for gas detection applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Fiber Optic Sensors · Gas Sensing Nanomaterials and Sensors · Spectroscopy and Laser Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

City, University of London 1 , Northampton Square, Clerkenwell, London EC1V 0HB, United Kingdom

Electrical Engineering Program, COPPE, Universidade Federal do Rio de Janeiro 2 , 21941-972 Rio de Janeiro, RJ, Brazil

Brazilian Center for Physics Research 3 , Xavier Sigaud 150, 22290-180 , RJ, Brazil

Rio de Janeiro 3 , Xavier Sigaud 150, 22290-180 , RJ, Brazil

Nanotechnology Engineering Program, COPPE, Universidade Federal do Rio de Janeiro 4 , 21941-972 Rio de Janeiro, RJ, Brazil

Funding

Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro

References (27)

Show source-provided references
1. American Conference of Governmental Industrial Hygienists · 2000
2. Anal. Chem. · 1962 · 34 · 150210.1021/ac60191a001 ↗
3. Talanta · 2000 · 52 · 77710.1016/S0039-9140(00)00421-5 ↗
4. J. Appl. Phys. · 1996 · 80 · 605010.1063/1.363562 ↗
5. Sens. Actuators B Chem. · 2003 · 93 · 56610.1016/S0925-4005(03)00229-6 ↗
6. J. Vac. Sci. Technol. A · 1996 · 14 · 35910.1116/1.579901 ↗
7. J. Vac. Sci. Technol. A · 2001 · 19 · 276210.1116/1.1403716 ↗
8. Sens. Actuators B Chem. · 2001 · 77 · 46310.1016/S0925-4005(01)00726-2 ↗
9. Talanta · 1997 · 44 · 109910.1016/S0039-9140(96)02202-3 ↗
10. Sens. Actuators B Chem. · 2003 · 90 · 21110.1016/S0925-4005(03)00030-3 ↗
11. Anal. Chim. Acta · 1998 · 359 · 12510.1016/S0003-2670(97)00633-8 ↗
12. Langmuir · 1992 · 8 · 66810.1021/la00038a060 ↗
13. Sens. Actuators B Chem. · 2014 · 195 · 21510.1016/j.snb.2014.01.045 ↗
14. Sens. Actuators B Chem. · 1999 · 60 · 2710.1016/S0925-4005(99)00240-3 ↗
15. Appl. Optics · 2007 · 46 · 248110.1364/AO.46.002481 ↗
16. Rev. Sci. Instrum. · 1997 · 68 · 430910.1063/1.1148392 ↗
17. 2010 · 441
18. IEEE Photonics Technol. Lett. · 2004 · 16 · 114910.1109/LPT.2004.824972 ↗
19. Appl. Phys. Lett. · 1993 · 62 · 103510.1063/1.108786 ↗
20. 1992
21. Sensors · 2010 · 10 · 208810.3390/s100302088 ↗
22. Phys. Rev. B · 1992 · 46 · 246010.1103/PhysRevB.46.2460 ↗
23. J. Vac. Sci. Technol. A · 1996 · 14 · 316410.1116/1.580207 ↗
24. J. Appl. Phys. · 1994 · 76 · 379710.1063/1.357383 ↗
25. Sens. Actuators B Chem. · 1990 · 1 · 9710.1016/0925-4005(90)80180-8 ↗
26. Phys. Chem. Chem. Phys. · 2013 · 15 · 1186810.1039/c3cp51525g ↗
27. Laser Photon. Rev. · 2013 · 7 · 8310.1002/lpor.201100039 ↗