Abstract

Biosensor stability and performance are known to benefit from the nanoscale confinement of its immobilized protein or enzyme components due to its ability to mimic the natural environment of these biomolecules. In this study, the enzyme cholesterol oxidase (ChOx) was adsorbed on pores created on polystyrene-block-polymethyl methacrylate films. A combination of fluorescence microscopy and atomic force microscopy analysis reveals the presence of ChOx on the polystyrene domain pores. Absorbance measurements on a cholesterol solution exposed to the enzyme deposited on the block copolymer reveal the occurrence of catalysis. The results of this study demonstrate the feasibility of immobilizing enzymes in a polymer-derived bioinspired platform that can be utilized for biosensing applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Nanofabrication and Lithography Techniques · Force Microscopy Techniques and Applications · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Nanoprobe Laboratory for Bio- & Nanotechnology and Biomimetics, The Ohio State University , Columbus, Ohio 43210

References (32)

Show source-provided references
1. Biosens. Bioelectron. · 2007 · 22 · 184110.1016/j.bios.2006.09.018 ↗
2. 2010
3. Enzyme Microb. Technol. · 2011 · 48 · 10710.1016/j.enzmictec.2010.10.003 ↗
4. 2012
5. Proc. Natl. Acad. Sci. U.S.A. · 2005 · 102 · 475310.1073/pnas.0409630102 ↗
6. Biosens. Bioelectron. · 2007 · 22 · 265010.1016/j.bios.2006.10.040 ↗
7. Mol. Biol. Cell · 1999 · 10 · 78510.1091/mbc.10.3.785 ↗
8. J. Biomed. Mater. Res. Part A · 2004 · 69 · 52510.1002/jbm.a.30026 ↗
9. J. Biomed. Mater. Res. Part A · 2012 · 100 · 97810.1002/jbm.a.34033 ↗
10. Biochemistry · 2001 · 40 · 1128910.1021/bi0155504 ↗
11. Langmuir · 2008 · 24 · 1376510.1021/la8015707 ↗
12. J. Am. Chem. Soc. · 2004 · 126 · 1222410.1021/ja046900n ↗
13. J. Phys. Chem. B · 2005 · 109 · 1227710.1021/jp050535k ↗
14. Biosens. Bioelectron. · 2005 · 20 · 167410.1016/j.bios.2004.07.019 ↗
15. Biomacromolecules · 2008 · 9 · 102710.1021/bm701343m ↗
16. Lab Chip · 2010 · 10 · 330010.1039/c0lc00127a ↗
17. Biosens. Bioelectron. · 1997 · 12 · 23310.1016/S0956-5663(97)85341-9 ↗
18. Bioelectrochemistry · 2001 · 54 · 1710.1016/S0302-4598(01)00105-2 ↗
19. Biosens. Bioelectron. · 2001 · 16 · 84910.1016/S0956-5663(01)00208-1 ↗
20. Anal. Bioanal. Chem. · 2007 · 388 · 105910.1007/s00216-007-1187-1 ↗
21. Biosens. Bioelectron. · 2011 · 26 · 303710.1016/j.bios.2010.12.009 ↗
22. HFSP J. · 2007 · 1 · 16910.2976/1.2778852 ↗
23. 2011
24. Ultramicroscopy · 2006 · 106 · 64510.1016/j.ultramic.2005.12.020 ↗
25. Ultramicroscopy · 2010 · 110 · 84410.1016/j.ultramic.2010.03.002 ↗
26. Clin. Chem. · 1969 · 15 · 117110.1093/clinchem/15.12.1171 ↗
27. Clin. Chem. · 1974 · 20 · 79410.1093/clinchem/20.7.794 ↗
28. Langmuir · 2005 · 21 · 665210.1021/la050331v ↗
29. Langmuir · 2009 · 25 · 1214410.1021/la901658w ↗
30. Macromolecules · 2004 · 37 · 182510.1021/ma021765p ↗
31. ACS Nano · 2009 · 3 · 392710.1021/nn900914q ↗
32. Brandrup · 1999