Use of ellipsometry to monitor methane plasma ion implant process
Source abstract
Abstract
Plasma implantation processes, like the Applied Materials PLAD™ ion implant process, directly expose a wafer to plasma. For some plasma chemistries, this exposure leads to both deposition and implant damage. Standard industrial metrologies like thermal wave are only sensitive to implant damage, but device results can depend on other implant metrics, such as implant depth and conformality. Deposition can affect these metrics without affecting the implant damage. Ellipsometry is the ideal industrial technique to measure the deposition left by a plasma implant process. However, it has not been used to evaluate deposition thickness in the presence of implant damage. This paper describes the development of an ellipsometry model that can be used to simultaneously monitor the deposited layer thickness and the implant damage produced by a methane plasma implant process. The extracted thickness of the implanted damage layer tracks thermal wave across a wide range of process parameters, and through an extended “marathon” test. The ellipsometry model is also consistent with a “deposition-only” ellipsometry model that matches scanning electron microscopy thickness measurements when implant damage is absent. For the methane recipe that was studied, ellipsometry can detect process excursions in plasma implantation that cannot be detected with established implant process monitors.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ion-surface interactions and analysis · Optical Coatings and Gratings · Surface Roughness and Optical Measurements
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Varian Semiconductor Equipment, Applied Materials , 35 Dory Rd, Gloucester, Massachusetts 01930
References (14)
Show source-provided references
1. Appl. Opt. · 1983 · 22 · 316910.1364/AO.22.003169 ↗
2. J. Opsal, U.S. patent 5,074,669 (12 December 1989).10.1007/BF03296167 ↗
3. J. Vac. Sci. Technol. A · 2013 · 31 · 05850210.1116/1.4809747 ↗
4. The role of metrology and inspection in semiconductor processing
5. Spectroscopic ellipsometry of ion-implantation-induced damage10.5772/1881 ↗
6. Phys. Status Solidi C · 2008 · 5 · 91110.1002/pssc.200778340 ↗
7. Rev. Sci. Instrum. · 1969 · 40 · 76110.1063/1.1684062 ↗
8. 1998
9. Opt. Mater. · 1992 · 1 · 4110.1016/0925-3467(92)90015-F ↗
10. Appl. Phys. Lett. · 1996 · 69 · 37110.1063/1.118064 ↗
11. 2009
12. J. Appl. Phys. · 1984 · 55 · 76410.1063/1.333135 ↗
13. Ann. Phys. · 1871 · 219 · 27210.1002/andp.18712190612 ↗
14. Phys. Rev. B. · 1983 · 27 · 98510.1103/PhysRevB.27.985 ↗