journal article·2022-05-01Open access

Lamellae preparation for atomic-resolution STEM imaging from ion-beam-sensitive topological insulator crystals

Abdulhakim Bake, Weiyao Zhao, David Mitchell, Xiaolin Wang, Mitchell Nancarrow, David Cortie

Abstract

Good specimen quality is a key factor in achieving successful scanning transmission electron microscope analysis. Thin and damage-free specimens are prerequisites for obtaining atomic-resolution imaging. Topological insulator single crystals and thin films in the chalcogenide family such as Sb2Te3 are sensitive to electron and ion beams. It is, therefore, challenging to prepare a lamella suitable for high-resolution imaging from these topological insulator materials using standard focused ion-beam instruments. We have developed a modified method to fabricate thin focused ion-beam (FIB) lamellae with minimal ion-beam damage and artifacts. The technique described in the current study enables the reliable preparation of high-quality transmission electron microscope (TEM) specimens necessary for studying ultra-thin surface regions. We have successfully demonstrated that the careful selection of FIB milling parameters at each stage minimizes the damage layer without the need for post-treatment.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Topological Materials and Phenomena · Photorefractive and Nonlinear Optics · Advanced Semiconductor Detectors and Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute for Superconducting and Electronic Materials, University of Wollongong 1 , North Wollongong, NSW 2500, Australia

ARC Centre of Excellence in Future Low-Energy Electronics Technologies, University of Wollongong 2 , North Wollongong, NSW 2500, Australia

ARC Centre of Excellence in Future Low-Energy Electronics Technologies, Monash University 3 , Clayton, VIC 3800, Australia

Electron Microscopy Centre, University of Wollongong 4 , North Wollongong, NSW 2500, Australia

Australian Nuclear Science and Technology Organisation 5 , Lucas Heights, NSW 2234, Australia

Funding

Australian Research Council · Centre of Excellence in Future Low-Energy Electronics Technologies, Australian Research Council · Australian Research council · Australian Institute of Nuclear Science and Engineering

References (23)

Show source-provided references
1. Nature · 2010 · 464 · 19410.1038/nature08916 ↗
2. Phys. Rev. Lett. · 2005 · 95 · 14680210.1103/PhysRevLett.95.146802 ↗
3. Rev. Mod. Phys. · 2010 · 82 · 304510.1103/RevModPhys.82.3045 ↗
4. Science · 2006 · 314 · 175710.1126/science.1133734 ↗
5. Nat. Phys. · 2009 · 5 · 43810.1038/nphys1270 ↗
6. Science · 2009 · 325 · 593710.1126/science.1173034 ↗
7. Nano Lett. · 2013 · 13 · 285110.1021/nl401186d ↗
8. APL Mater. · 2020 · 8 · 07090210.1063/5.0014113 ↗
9. Appl. Phys. Lett. · 2020 · 116 · 19241010.1063/5.0006447 ↗
10. Nano Lett. · 2021 · 21 · 508310.1021/acs.nanolett.1c00141 ↗
11. Micron · 2012 · 43 · 90210.1016/j.micron.2012.03.008 ↗
12. J. Microsc. · 2010 · 238 · 310.1111/j.1365-2818.2009.03341.x ↗
13. Microelectron. Reliab. · 2015 · 55 · 211910.1016/j.microrel.2015.07.005 ↗
14. Ultramicroscopy · 1993 · 52 · 10110.1016/0304-3991(93)90025-S ↗
15. Ultramicroscopy · 1998 · 70 · 16110.1016/S0304-3991(97)00120-4 ↗
16. Mater. Lett. · 2006 · 60 · 210.1016/S0167-577X(05)00999-7 ↗
17. J. Microsc. Microanal. · 2013 · 19 · S510.1017/S1431927613012282 ↗
18. J. Vac. Sci. Technol. B · 1995 · 13 · 96210.1116/1.588213 ↗
19. ACS Nano · 2012 · 6 · 883710.1021/nn303944f ↗
20. Microsc. Res. Tech. · 2012 · 75 · 155010.1002/jemt.22099 ↗
21. Nucl. Instrum. Methods Phys. Res. B · 2010 · 268 · 181810.1016/j.nimb.2010.02.091 ↗
22. Sci. Rep. · 2017 · 7 · 1346610.1038/s41598-017-13863-6 ↗
23. Appl. Phys. Lett. · 2014 · 105 · 24210610.1063/1.4904936 ↗