Monolayer calibration of endofullerenes with x-ray absorption from implanted keV ion doses
Source abstract
Abstract
X-ray absorption spectroscopy (XAS) has the highest sensitivity for chemical element detection on surfaces. With this approach, small amounts of lanthanide-containing endofullerene molecules (Ho3N@C80) have been measured by total electron yield at a low flux bending magnet beamline. The monolayer coverage is calibrated by extrapolating the signals of constant doses (3×1014 cm−2) of Ho ions implanted into SiO2 with energies between 2 and 115 keV. At room temperature, the Ho XAS spectra of the molecules and implanted ions indicate trivalent but not identical Ho ground states. Still, this approach demonstrates a way for calibration of small coverages of molecules containing open core-shell elements.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Diamond and Carbon-based Materials Research · Graphene research and applications · Ion-surface interactions and analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Physik-Institut, University of Zürich 1 , Zürich CH-8057,
Department of Physics and Astronomy, Uppsala University 2 , Uppsala SE-75120,
Graphene Labs, Istituto Italiano di Tecnologia 3 , Genova IT-16163,
Leibniz-Institute for Solid State and Materials Research (IFW) 4 , Dresden D-01069,
Swiss Light Source, Paul Scherrer Institut (PSI) 5 , Villigen CH-5232,
Funding
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung · Swedish Research Council VR-RFI · HORIZON EUROPE Framework Programme
References (23)
Show source-provided references
1. Nanotechnology · 2018 · 29 · 11570510.1088/1361-6528/aaa6ef ↗
2. Biochim. Biophys. Acta Biomembr. · 1990 · 1023 · 32510.1016/0005-2736(90)90123-6 ↗
3. 2001 International Microprocesses and Nanotechnology Conference--Digest of Papers10.1109/IMNC.2001.984179 ↗
4. Surf. Sci. · 1996 · 357-358 · 71710.1016/0039-6028(96)00252-X ↗
5. Powder Diffr. · 2023 · 38 · 11210.1017/S088571562300012X ↗
6. J. Phys.: Conf. Ser. · 2013 · 430 · 01213110.1088/1742-6596/430/1/012131 ↗
7. Phys. Rev. B · 1985 · 32 · 510710.1103/PhysRevB.32.5107 ↗
8. Phys. Rev. B · 2009 · 80 · 08140310.1103/PhysRevB.80.081403 ↗
9. J. Am. Chem. Soc. · 2018 · 140 · 1095510.1021/jacs.8b06983 ↗
10. Phys. Rev. Mater. · 2019 · 3 · 01440910.1103/PhysRevMaterials.3.014409 ↗
11. Phys. Rev. Lett. · 2015 · 114 · 08720110.1103/PhysRevLett.114.087201 ↗
12. Phys. Rev. Mater. · 2023 · 7 · 08600110.1103/PhysRevMaterials.7.086001 ↗
13. J. Vac. Sci. Technol. A · 2022 · 40 · 05320510.1116/6.0001961 ↗
14. Phys. Rev. Mater. · 2023 · 7 · 05580110.1103/PhysRevMaterials.7.055801 ↗
15. J. Synchrotron Rad. · 2017 · 24 · 35410.1107/S1600577516018646 ↗
16. Adv. Mater. Interfaces · 2024 · 2024 · 230093510.1002/admi.202300935 ↗
17. Nano Lett. · 2020 · 20 · 331310.1021/acs.nanolett.0c00172 ↗
18. J. Sci. Instrum. · 1960 · 37 · 24610.1088/0950-7671/37/7/307 ↗
19. J. Instrum. · 2022 · 17 · P0401110.1088/1748-0221/17/04/P04011 ↗
20. Phys. Rev. B · 2012 · 85 · 12513310.1103/PhysRevB.85.125133 ↗
21. Nucl. Instrum. Meth. Phys. Res. Sect. B Beam Interact. Mater. Atoms · 1988 · 35 · 1710.1016/0168-583X(88)90093-6 ↗
22. Thin Solid Films · 1993 · 235 · 18910.1016/0040-6090(93)90264-P ↗
23. Phys. Rev. B · 1988 · 37 · 245010.1103/PhysRevB.37.2450 ↗