journal article·1991-11-01

Electron cyclotron resonance plasma chemical vapor deposition of large area uniform silicon nitride films

S. Y. Shapoval, V. T. Petrashov, O. A. Popov, M. D. Yoder, P. D. Maciel, C. K. C. Lok

Publisher page

Abstract

Electron cyclotron resonance plasma (f=2.45 GHz, microwave power P=200–800 W) generated in a radially uniform magnetic field (B=875–1000 G) was used to produce a large area (15–20 cm diam) uniform plasma stream at 20–30 cm from the source output. Low temperature (70–300 °C) silicon nitride films with a thickness of 800–3000 Å were deposited on 5–20 cm diameter wafers with deposition rates of 100–350 Å/min. Film thickness uniformity was ±1% for 7.6–10.0 cm diam wafers, ±3% for 15 cm diam wafers, and ±9% for 20.0 cm diam wafers. It was found that the film deposition rate Wg increased linearly with the silane flow rate, while Wg increased slower than power 1/2 with the nitrogen flow rate. The film refractive index was 1.9–2.0 at a silane/nitrogen flow rate ratio of 0.40–0.6. The effects of plasma density and its profile on the film growth rate and uniformity are discussed.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Plasma Diagnostics and Applications · Semiconductor materials and devices

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Microscience, Inc. Norwell, Massachusetts 02061

References