Optimized microwave coupling in an electron cyclotron resonance etch tool
Source abstract
Abstract
We have improved the operational characteristics of an electron cyclotron resonance (ECR) plasma etch tool by optimizing the coupling of the 2.45-GHz microwaves to the plasma. Improved coupling is achieved by using a right-hand circularly polarized (r.h.c.p.) mode which is matched to the plasma impedance through a quarter-wave transformer. This design reduces microwave reflected power typically to <5% of the incident power without external tuning and simplifies control of the plasma etch tool operation. The r.h.c.p. mode is azimuthally symmetric when averaged over one microwave cycle and adapts easily to ECR source chambers of larger radii. We present an analytic model, the results of which are in good agreement with our experiments for microwave coupling in ECR etch tools.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Particle accelerators and beam dynamics · Gyrotron and Vacuum Electronics Research · Plasma Diagnostics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Princeton Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08544
Princeton Plasma Physics Laboratory and Department of Chemical Engineering, Princeton University, Princeton, New Jersey 08544
Department of Chemical Engineering, Princeton University, Princeton, New Jersey 08544
References
Reference metadata was not supplied for this record.