Initial conditioning of the TFTR vacuum vessel
Source abstract
Abstract
We report on the initial conditioning of the Tokamak Fusion Test Reactor (TFTR) vacuum vessel prior to the initiation of first plasma discharges, and during subsequent operation with high power Ohmically heated plasmas. Following evacuation of the 86-m3 vessel with the 104 1/s high vacuum pumping system, the vessel was conditioned by a 15-A dc glow discharge in H2 at a pressure of 5 mTorr. Rapid-pulse discharge cleaning was used subsequently to preferentially condition the graphite plasma limiters. The effectiveness of the discharge cleaning was monitored by measuring the exhaust rates of the primary discharge products (CO/C2H4, CH4, and H2O). After 175 h of glow discharge treatment, the equivalent of 50 monolayers of C and O was removed from the vessel, and the partial pressures of impurity gases were reduced to the range of 10−9–10−10 Torr.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Magnetic confinement fusion research · Fusion materials and technologies · Particle accelerators and beam dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Princeton Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08544
References
Reference metadata was not supplied for this record.