journal article·2005-07-01

Selective detection of Cr(VI) using a microcantilever electrode coated with a self-assembled monolayer

F. Tian, V. I. Boiadjiev, L. A. Pinnaduwage, G. M. Brown, T. Thundat

Publisher page

Abstract

We have demonstrated detection of Cr(VI) ions using functionalized microcantilevers under electrochemical control. Au-coated microcantilever working electrodes are modified with self-assembled monolayers of 4-mercaptopyridine (4-mPy) in sulfuric acid solution. Differential surface stress changes at the modified microcantilever have been measured as a function of applied potential while simultaneously measuring the current-potential response by cyclic voltammetry. The selective adsorption of Cr(VI) on 4-mPy monolayer-coated microcantilever electrode is attributed to hydrogen bonding. The stressogram (first derivative of surface stress of microcantilever with respect to potential versus electrode potential) suggests that a small amount of an intermediate oxidation state of chromium is retained at the 4-mPy monolayer, and this intermediate reduction product of Cr(VI) can be reversibly oxidized on the surface. Our results demonstrate that changes of differential surface stress due to the adsorption-controlled electrochemical reaction can be observed at high sensitivity. This potential controlled microcantilever technique offers insights into the behavior of the solid-liquid interface during electrochemical reactions at modified electrodes.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Mechanical and Optical Resonators · Force Microscopy Techniques and Applications · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Oak Ridge National Laboratory Life Sciences Division, , Oak Ridge, Tennessee 37831

University of Tennessee - Knoxville Department of Physics, , Knoxville, Tennessee 37996

Oak Ridge National Laboratory Life Sciences Division, , Oak Ridge, Tennessee 37831 and Department of Physics, , Knoxville, Tennessee 37996

University of Tennessee - Knoxville Life Sciences Division, , Oak Ridge, Tennessee 37831 and Department of Physics, , Knoxville, Tennessee 37996

Oak Ridge National Laboratory Chemical Sciences Division, , Oak Ridge, Tennessee 37831

References (22)

Show source-provided references
1. Appl. Phys. Lett. · 1994 · 64 · 289410.1063/1.111407 ↗
2. J. Appl. Phys. · 1995 · 77 · 361810.1063/1.359562 ↗
3. Microscale Thermophys. Eng. · 1997 · 1 · 18510.1080/108939597200214 ↗
4. Anal. Chem. · 2001 · 73 · 157210.1021/ac0013103 ↗
5. Anal. Chem. · 2002 · 74 · 361110.1021/ac0255781 ↗
6. Chem. Commun. (Cambridge) · 2000 · 6 · 457
7. Proc. Natl. Acad. Sci. U.S.A. · 2001 · 98 · 156010.1073/pnas.031362498 ↗
8. Proc. R. Soc. London, Ser. A · 1909 · 82 · 17210.1098/rspa.1909.0021 ↗
9. Proc. Phys. Soc., London, Sect. A · 1950 · 63 · 44410.1088/0370-1298/63/5/302 ↗
10. Langmuir · 2002 · 18 · 693510.1021/la025806m ↗
11. Biosens. Bioelectron. · 2002 · 17 · 33710.1016/S0956-5663(01)00270-6 ↗
12. Sens. Actuators B · 2001 · 72 · 223
13. Sensor Lett. · 2004 · 2 · 110.1166/sl.2004.021 ↗
14. Anal. Chem. · 1997 · 69 · 89410.1021/ac9607525 ↗
15. Science · 1997 · 276 · 202110.1126/science.276.5321.2021 ↗
16. Mech. Mater. · 1996 · 23 · 314
17. Langmuir · 2003 · 19 · 682610.1021/la030052c ↗
18. 2001 · 589
19. J. Chem. Eng. Data · 1998 · 43 · 89510.1021/je980080a ↗
20. 2000 · 858
21. J. Electroanal. Chem. · 2000 · 489 · 6810.1016/S0022-0728(00)00198-4 ↗
22. Langmuir · 1993 · 9 · 38510.1021/la00026a005 ↗