journal article·1987-07-01

Combining transmission probabilities of different diameter tubes

D. J. Santeler, M. D. Boeckmann

Publisher page

Abstract

Numerical simulations were used to study the molecular flow transmission probability through two tubes of different diameters connected in series. It is well known that Oatley’s simple area ratio correction to the exit loss is inexact due to beaming of the gas from one tube to the next. Many months of computer time on a PC-AT with 80287 numerical processing unit and a VAX-780 were required to obtain sufficiently accurate data on numerous different diameter ratios in order to allow for high-accuracy curve fitting to various potential correction equations for interpolation. The method of analysis used was similar to one by Santeler for two tubes of the same diameter in series. It was found that Oatley’s area correction has a maximum error of 5%. A curve-fit equation is provided that reduces this error to 0.6%.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spectroscopy and Laser Applications · Laser Design and Applications · Microfluidic and Capillary Electrophoresis Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Process Applications, Inc., Oak Ridge, Tennessee 37830

Vacuum Technology, Inc., Oak Ridge, Tennessee 37830

References

Reference metadata was not supplied for this record.