Precise measurement of flow rates of vaporized tetraethylgermanium carried by an inert gas
Source abstract
Abstract
The ‘‘rate-of-rise’’ technique has been applied for the measurement of the flow rate of tetraethylgermanium carried in a stream of argon. A very precise time counter designed and constructed for this purpose is described. A simple model is presented where the flow rate of the vapor is proportional to its partial pressure and to the flow rate of the carrier gas and inversely proportional to the partial pressure of the carrier gas. The assumed applicability of the equation of state of the ideal gas to the discussed system is successfully tested by means of the flow rate dependence on temperature in the range from −19 to 20 °C and its comparison with data computed from the Clausius–Clapeyron equation. Finally thermodynamic properties of tetraethylgermanium namely vaporization enthalpy and saturated vapour pressure at standard temperature are calculated from the results of flow rate measurements.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Advanced Sensor Technologies Research · Chemical Thermodynamics and Molecular Structure
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institut f ür Allgemeine Elektrotechnik und Elektronik, Technische Universität Wien, Gusshausstrasse 27–29, Vienna, A-1040 Austria
Ludwig Boltzmann Institut fur Biomedizinische Mikrotechnik, Technische Universität Wien, Gusshausstrasse 27–29, Vienna, A-1040 Austria
References
Reference metadata was not supplied for this record.