Optimization of an electron cyclotron resonance etch process using full wafer charge coupled device interferometry
Source abstract
Abstract
Full wafer charge coupled device interferometry is a new technique that can be used for in situ monitoring of plasma etching. The use of this technique to optimize an electron cyclotron resonance etch process for TaSiN and its application to x-ray mask fabrication are presented. Fine tuning of the etch process was performed by optimizing the microwave power and the collimating magnet current. Under optimized conditions, etch rate uniformity (3σ) across a 4 in. substrate was as low as 2%. The full wafer interferometer enables in situ uniformity measurements, thus minimizing process development time. The etch process has been used to successfully fabricate sub-0.25 μm x-ray masks.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advancements in Photolithography Techniques · Semiconductor materials and devices · Plasma Diagnostics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Motorola PCRL, Tempe, Arizona 85284
Low Entropy Systems, Boston, Massachusetts 02135
References
Reference metadata was not supplied for this record.