journal article·1993-07-01

Double Langmuir probe diagnostic of a resonant cavity microwave discharge

W. McColl, C. Brooks, M. L. Brake

Publisher page

Abstract

An Asmussen resonant cavity operating at 2.45 GHz provides the basis for the application of probe theory to a microwave discharge. A double Langmuir probe is inserted into a discharge produced by a microwave resonant cavity. Typical operating pressures range from 0.5 to 50 Torr in helium, with continuous wave microwave powers ranging from 60 to 120 W at 2.45 GHz. Typical probe data indicates electron densities in the range of 1011–1012 cm−3 with electron temperatures of 5 to 20 eV. The probe data is compared with the results of a model based upon the electromagnetics of the discharge.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Plasma Diagnostics and Applications · Plasma Applications and Diagnostics · Particle accelerators and beam dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Nuclear Engineering, University of Michigan, Ann Arbor, Michigan 48109-2104

References

Reference metadata was not supplied for this record.