Pumping of methane by St707 at low temperatures

J. P. Hobson, R. Chapman

Publisher page

Abstract

A simple means of pumping small leak rates of methane is frequently required in long-term sealed-off devices such as evacuated solar absorbers. In this paper we examine, in this context, a chemisorption or catalytic pump the SAES getter St707. After suitable activation in an ultrahigh vacuum system a small sample of St707 (2.7×3 cm), with heater external to the vacuum system, was exposed to a methane leak as the sample temperature was raised in steps from room temperature to 400 °C, the highest temperature used. Pumping was first detected at 100 °C and at 400 °C the pumping speed was 2×10−3 l s−1 cm−2 (pumping area assumed 8 cm2), after 0.34 Torr l of methane had been pumped. Care was taken to distinguish these small pumping speeds from ionic pumping by the gages. The conclusion is that the St707 getter is suitable as a methane pump of low speed at low temperatures and pressures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Atomic and Subatomic Physics Research · Scientific Measurement and Uncertainty Evaluation · Geophysics and Sensor Technology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Electrical Engineering Division, National Research Council, Ottawa, Canada K1A OR6