journal article·2010-05-01

Bent belt-beam gauge: Extending low-pressure measurement limits in a hot-cathode ionization vacuum gauge by combining multiple methods

Fumio Watanabe

Publisher page

Abstract

A commercially viable, extremely high vacuum hot-cathode ionization gauge that can measure pressures as low as 5.4×10−12 Pa, by reducing the limits imposed by soft x rays, electron-stimulated desorption (ESD), and outgassing, is reported. The gauge construction includes a cylindrical grid, which is closed at both ends; ions are drawn from the grid through a long, axial slit made in the cylindrical surface. Thus, the ion beam that emerges forms a “belt.” This beltlike ion beam is guided on a curved path by a cylindrical sector deflector and terminates on a plate collector arranged after a beam trajectory rotation of 230°. These elements are embedded in a solid cylinder of 0.2% BeCu alloy, which has a low emissivity (radiation factor) and high thermal conductivity. As a result, the effects of heat radiation and outgassing (caused by the hot-cathode filament) and soft x-ray photoemission (the grid is the soft x-ray source) are reduced in the deflector/collector region. This electrode arrangement can also greatly decrease the flux of soft x rays and ESD in the direction of the belt ion beam because it sets to 90° the angle between the extracted gas-phase ion beam and the maximum flux of soft x rays and ESD. In addition, it achieves an extremely low-pressure measurement limit by minimizing loss in the ion transport, and because the collector is well hidden, being located after the large deflection of the ion beam.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Plasma Diagnostics and Applications · Scientific Measurement and Uncertainty Evaluation · Electrostatic Discharge in Electronics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Vaclab Incorporated , SOHO Building, 2-10-2 Matsushiro, Tsukuba, Ibaraki 305-0035, Japan

References (29)

Show source-provided references
1. 1947 · 14
2. Rev. Sci. Instrum. · 1950 · 21 · 57110.1063/1.1745653 ↗
3. J. Vac. Sci. Technol. A · 1987 · 5 · 321510.1116/1.574840 ↗
4. J. Vac. Sci. Technol. A · 1992 · 10 · 266510.1116/1.577956 ↗
5. J. Vac. Sci. Technol. A · 2003 · 21 · S110.1116/1.1599871 ↗
6. J. Chem. Phys. · 1964 · 41 · 331110.1063/1.1725730 ↗
7. Can. J. Phys. · 1964 · 42 · 88610.1139/p64-083 ↗
8. J. Vac. Sci. Technol. · 1966 · 3 · 17310.1116/1.1492470 ↗
9. J. Vac. Sci. Technol. · 1972 · 9 · 12610.1116/1.1316528 ↗
10. 1980 · 199
11. Rev. Sci. Instrum. · 1966 · 37 · 165210.1063/1.1720076 ↗
12. J. Vac. Sci. Technol. A · 1984 · 2 · 5410.1116/1.572624 ↗
13. J. Vac. Sci. Technol. A · 1985 · 3 · 219210.1116/1.572888 ↗
14. J. Vac. Sci. Technol. A · 1987 · 5 · 24210.1116/1.574112 ↗
15. J. Vac. Sci. Technol. A · 1990 · 8 · 389010.1116/1.576469 ↗
16. J. Vac. Sci. Technol. A · 1991 · 9 · 274410.1116/1.577192 ↗
17. J. Vac. Sci. Technol. A · 1992 · 10 · 333310.1116/1.577821 ↗
18. J. Vac. Sci. Technol. A · 1993 · 11 · 43210.1116/1.578749 ↗
19. J. Vac. Sci. Technol. A · 1993 · 11 · 162010.1116/1.578468 ↗
20. J. Vac. Sci. Technol. A · 1995 · 13 · 49710.1116/1.579387 ↗
21. Vacuum · 1996 · 47 · 56710.1016/0042-207X(96)00021-8 ↗
22. Vacuum · 1999 · 52 · 33310.1016/S0042-207X(98)00314-5 ↗
23. J. Vac. Sci. Technol. A · 1999 · 17 · 346710.1116/1.582084 ↗
24. J. Vac. Sci. Technol. A · 2002 · 20 · 122210.1116/1.1479736 ↗
25. J. Vac. Sci. Technol. A · 1994 · 12 · 323310.1116/1.579243 ↗
26. Tully · 1983
28. J. Vac. Sci. Technol. A · 2004 · 22 · 18110.1116/1.1635390 ↗
29. J. Vac. Sci. Technol. A · 1999 · 17 · 202610.1116/1.581722 ↗