journal article·1988-07

Phosphorus liquid metal ion source using a Pt–P–Sb alloy

K. Umemura, Y. Madokoro, S. Shukuri, T. Ohnishi, T. Ishitani

Publisher page

Abstract

A phosphorus liquid metal ion source using a Pt–P–Sb alloy has been newly developed. The ion emission characteristics such as mass‐separated ion intensity, energy spread, and long‐term beam stability are described. It is found that the P2+ flux has the highest intensity with respect to charged P ions and is mass separable with a low mass resolution of m/Δm≂2. The source lifetime of more than 200 h has been obtained. A fine scanning ion microscope image made with a 140‐keV P2+ focused ion beam has shown considerable promise for maskless P ion implantation.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Materials Characterization Techniques · Ion-surface interactions and analysis · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References