Investigation of vacuum system requirements for a 5km baseline gravitational-wave detector
Source abstract
Abstract
Gravitational-wave laser interferometer detectors use a pair of cylindrical vacuum tubes, placed perpendicular to each other, in which the partial pressure of hydrogen is required to be ∼10−9mbar to obtain residual gas-phase noise of ∼10−25Hz−1∕2. Because total strain sensitivity decreases proportionally to arm length, it is advantageous to use longer arm-length interferometers. The vacuum-tube diameters are set by the light-scattering requirements, and also by the possible need for additional optical cavities within the tube. Here, the authors investigate the balance between achievable vacuum and tube diameter for various pumping conditions. For a 5km arm-length interferometer, they consider whether there is an advantage in reduced tube diameter. They also consider the impact of baffles. They show that the vacuum performance depends critically on the stainless-steel outgassing rate, which is limited by the tube conductance, and requires an outgassing rate <5×10−15mbarlcm−2s−1. It is shown that a smaller-diameter tube needs additional pumps, and that, in general, there is a reduced safety margin for practical design. The vacuum performance depends only weakly on the vacuum-pumping speed for practical pumps and is only weakly degraded by baffles.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Frequency and Time Standards · Pulsars and Gravitational Waves Research · Cold Atom Physics and Bose-Einstein Condensates
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. 10.1103/PhysRevD.40.388410.1103/PhysRevD.40.3884 ↗
2. 10.1088/0264-9381/21/5/00510.1088/0264-9381/21/5/005 ↗
3. 10.1088/0264-9381/21/5/00210.1088/0264-9381/21/5/002 ↗
4. 10.1088/0264-9381/21/5/00610.1088/0264-9381/21/5/006 ↗
5. 10.1088/0264-9381/21/5/00410.1088/0264-9381/21/5/004 ↗
6. 10.1088/1464-4258/7/6/00110.1088/1464-4258/7/6/001 ↗
7. 10.1088/0264-9381/19/7/33110.1088/0264-9381/19/7/331 ↗
8. A. Weinstein, LIGO Report No. LIGO-P010042-01-D, 2001 (Internal report).
9. D. Coyne, LIGO Report No. LIGO-T040001-00-D, 2004 (Internal report).
10. Regehr M. W. · Opt. Lett. · 1995 · 20 · 150710.1364/OL.20.001507 ↗
11. 10.1088/1742-6596/32/1/01810.1088/1742-6596/32/1/018 ↗
12. 10.1063/1.114978310.1063/1.1149783 ↗
13. 10.1116/1.58242610.1116/1.582426 ↗
14. 10.1116/1.58096710.1116/1.580967 ↗
15. 10.1016/j.vacuum.2003.12.01210.1016/j.vacuum.2003.12.012 ↗
16. 10.1116/1.57977710.1116/1.579777 ↗
17. 10.1103/PhysRevD.56.608510.1103/PhysRevD.56.6085 ↗
18. 10.1016/0042-207X(93)90364-G10.1016/0042-207X(93)90364-G ↗
19. A. Roth,Vacuum Technology(North-Holland, Amsterdam, 1982), p. 82.
20. 10.1016/S0042-207X(00)00238-410.1016/S0042-207X(00)00238-4 ↗