journal article·2006-11-01

Influence of background gas pressure charging potential and target distance on the spot size ablated by single pulsed electron beam

Roberto S. Aga, Chase Cox, Akira Ueda, Enrique Jackson, W. E. Collins, Richard Mu

Publisher page

Abstract

The area of spot ablated by single pulsed electron beam has been measured as a function of pulsed electron deposition (PED) parameters. These parameters are background gas pressure, charging potential and target distance. A 50 nm thick film of silver on glass is used as ablation target in order to create a clear spot that can be measured. The spot area is found to reflect the power density of the pulsed electron beam and it can be varied by adjusting the PED parameters. These results are useful in the application of PED for material fabrication.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Plasma Diagnostics and Applications · ZnO doping and properties · Laser-induced spectroscopy and plasma

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Fisk University Department of Physics, , 1000 17th Ave. N., Nashville, Tennessee 37208

References (7)

Show source-provided references
1. IEEE Trans. Plasma Sci. · 1995 · 23 · 25810.1109/27.402311 ↗
2. Appl. Phys. Lett. · 1990 · 56 · 97310.1063/1.102596 ↗
3. Appl. Surf. Sci. · 2005 · 247 · 16910.1016/j.apsusc.2005.01.124 ↗
4. Mater. Sci. Eng. B. · 2005 · 119 · 21010.1016/j.mseb.2005.02.042 ↗
5. Appl. Phys. Lett. · 2004 · 84 · 148310.1063/1.1651326 ↗
6. Appl. Phys. Lett. · 2003 · 82 · 85310.1063/1.1541945 ↗
7. 1990 · 211