journal article·1994-11-01

Plasma diagnostics of a direct current arcjet diamond reactor. I. Electrostatic probe analysis

S. W. Reeve, W. A. Weimer

Publisher page

Abstract

Plasma parameters were determined for a direct current arcjet diamond chemical vapor deposition reactor. Electron temperatures and densities were measured using a floating double probe technique, yielding values ranging from 2.3 eV and 7×1011 cm−3 near the plasma gun nozzle to 0.4 eV and 1×109 cm−3 in the downstream and peripheral regions of the plasma. These results show that the plasma is weakly ionized, indicating that reactions involving electrons play a minor role in the macroscopic gas–phase chemistry though high energy products from these reactions may significantly affect film quality.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Diamond and Carbon-based Materials Research · Metal and Thin Film Mechanics · Vacuum and Plasma Arcs

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Chemistry Division, Research Department, Naval Air Warfare Center, China Lake, California 93555

References

Reference metadata was not supplied for this record.