journal article·1995-11-01

Time-resolved Fourier transform infrared emission as a plasma diagnostic

G. Hancock, J. P. Sucksmith

Publisher page

Abstract

Time-resolved infrared emission has been observed by means of a Fourier transform technique from plasmas of fluorinated hydrocarbons under conditions similar to those used in semiconductor surface processing. Emission has been detected from vibrationally excited precursors and reaction products, and examples are shown of emission from HF, CF4, CO2, and CF2O. The time dependences of the signals on plasma extinction give information on the production and relaxation mechanisms taking place. Equilibrated rotational and translational temperatures in the plasma are derived from quantum state distributions in HF. Blackbody emission is observed from both chamber surfaces and from a Si wafer placed in the plasma, and the time-resolved emission technique is used to measure the surface temperature under conditions in which strong molecular emissions are present.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Plasma Diagnostics and Applications · Plasma Applications and Diagnostics · Laser-induced spectroscopy and plasma

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ, United Kingdom

References

Reference metadata was not supplied for this record.