journal article·1999-07-01

Design and installation of a low particulate, ultrahigh vacuum system for a high power free-electron laser

H. F. Dylla, G. Biallas, L. A. Dillon-Townes, E. Feldl, G. R. Myneni, J. Parkinson, J. Preble, T. Siggins, S. Williams, M. Wiseman

Publisher page

Abstract

A high-average power (kW) infrared (IR) free-electron laser (FEL) is currently being commissioned for the Jefferson Laboratory FEL User Facility. The IR FEL is driven by a unique superconducting rf linac which is recirculated to recover electron beam power that is not radiated in the FEL. The design and installation of the vacuum system for the FEL involved particular attention to minimizing particulate contamination which could cause problems with the superconducting acceleration cavities and the high power FEL optics. Particulate contamination levels of all vacuum components were monitored during the cleaning process using laser scattering. Cleaning, transport, and installation procedures were developed to minimize the contamination of the complete system. We will summarize a data base we compiled of particulate contamination levels of the various components installed in the FEL vacuum system.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Surface Polishing Techniques · Advanced X-ray Imaging Techniques · Particle Accelerators and Free-Electron Lasers

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Thomas Jefferson Laboratory National Accelerator Facility, Newport News, Virginia 23606

References (3)

Show source-provided references
1. Proc. SPIE · 1996 · 2703 · 1510.1117/12.237725 ↗
2. Nucl. Instrum. Methods Phys. Res. B · 1998 · 144 · 18610.1016/S0168-583X(98)00307-3 ↗
3. J. Vac. Sci. Technol. A · 1993 · 11 · 2633