The application of scanning capacitance microscopy (SCM) to failure analysis of integrated circuits is described. Both top-down (parallel to the wafer surface) and cross-sectional SCM measurements were performed on product lots containing yield-limiting failures identified with electrical testing. The SCM images of functioning devices were compared with those of failed devices to note any differences in free carrier distributions. Using this approach, the root causes of failures in two different product lots—one bulk Si technology and one silicon-on-insulator technology—were identified. These two examples are described in detail, as well as the subsequent corrective actions taken to improve yield.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Integrated Circuits and Semiconductor Failure Analysis · Force Microscopy Techniques and Applications · Semiconductor materials and devices

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Microelectronics Development Laboratory, Sandia National Laboratories, Albuquerque, New Mexico 87185

References (9)

Show source-provided references
1. J. Vac. Sci. Technol. B · 2000 · 18 · 203410.1116/1.1306331 ↗
2. Appl. Phys. Lett. · 1999 · 74 · 27210.1063/1.123278 ↗
3. J. Appl. Phys. · 2000 · 87 · 148510.1063/1.372039 ↗
4. J. Vac. Sci. Technol. B · 2001 · 19 · 115410.1116/1.1384556 ↗
5. Rev. Sci. Instrum. · 1999 · 70 · 15810.1063/1.1149558 ↗
6. Appl. Phys. Lett. · 1998 · 72 · 69810.1063/1.120849 ↗
7. J. Vac. Sci. Technol. B · 2000 · 18 · 55510.1116/1.591231 ↗
8. Appl. Phys. Lett. · 1999 · 75 · 231910.1063/1.125002 ↗
9. Rev. Sci. Instrum. · 2003 · 74 · 12710.1063/1.1527722 ↗