Vacuum and multipactor performance of the hadron electron ring accelerator 52 MHz cavities
Source abstract
Abstract
Two 52 MHz radio‐frequency (rf) systems, including cavities and control systems, were fabricated and tested at Chalk River Laboratories and subsequently installed in the hadron electron ring accelerator (HERA) proton storage ring at DESY in Hamburg, West Germany. The cavities, with a volume exceeding 1 m3 and constructed entirely of aluminum alloy, must achieve the low operating pressures of the HERA proton storage ring and stably provide accelerating voltages from 15 to 150 kV. This paper reviews material choices, fabrication techniques, cleaning, and surface preparation, which have resulted in achievement of these operating goals. Computer simulations identifying potential multipactor areas, suppression of this multipactor, and rf vacuum conditioning processes are discussed.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Particle accelerators and beam dynamics · Particle Accelerators and Free-Electron Lasers · Gyrotron and Vacuum Electronics Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.