Study of a mechanically clamped cryo-chuck device in a high density plasma for deep anisotropic etching of silicon
Source abstract
Abstract
This article presents a study concerning a cryo-chuck device used in an inductively coupled plasma reactor for deep anisotropic etching of narrow trenches (2 μm wide) in silicon wafers of 5 in. in diameter. Thermal mechanisms in a mechanically clamped cryo-chuck system have been studied. First, wafer deformations have been measured in the chuck device. Deformations occur because of the helium backside pressure allowing thermal transfer to cool the wafer. In a second step, these deformations have been used in calculations considering the heat transfers in the substrate. In a last step, in situ temperature measurements have been made on wafers during a process using a LUXTRON® probe. This study shows the influence of the backside helium gap variation and the clamping ring temperature on the uniformity of substrate cooling.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Silicon and Solar Cell Technologies · Thin-Film Transistor Technologies · Advanced Surface Polishing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
GREMI, UMR 6606, Université d’ Orléans, B.P. 6759, 45067 Orléans Cedex 2, France
References (4)
Show source-provided references
1. Proc. SPIE · 1995 · 2639 · 22410.1117/12.221279 ↗
2. Jpn. J. Appl. Phys., Part 1 · 1991 · 30 · 331910.1143/JJAP.30.3319 ↗
3. Appl. Surf. Sci. · 1996 · 100/101 · 57910.1016/0169-4332(96)00342-X ↗
4. J. Vac. Sci. Technol. A · 1999 · 9 · 796