Polymethylmethacrylate membrane for fluid encapsulation and release in microfluidic systems
Source abstract
Abstract
A multipolymeric fabrication process using polymethlymethacrylate (PMMA) as a membrane layer was demonstrated for a robust dermal patch, called the bio-fluidic integrable transdermal (B–FIT) microsystem. B–FIT is a noninvasive microdevice, in the form of an adhesive patch, which samples biomolecules from interstitial fluids using controlled thermal ablation and encapsulated fluid that is released during biomolecule collection. Thus, a membrane material was needed that could encapsulate the fluid and easily liberate it, on demand, with minimal energy and compatibility with the fabrication process. PMMA was selected as the most promising membrane material for the B–FIT as against SU-8 since it had the required properties of low melting temperature (120–150 °C), good adhesion to pre-existing B–FIT materials (gold and SU-8), and could be easily spin-cast into thin uniform films. However, PMMA is not inert towards various solvents like acetone, photoresist developers, hence, a process was developed to protect PMMA from being attacked by the solvents used during the fabrication of the device. In this process, several strategies were employed such as crosslinking and application of thin protection layers on the PMMA. By exploring these fabrication strategies, PMMA was successfully patterned and the desired encapsulation and rupturing of the membrane was obtained.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: 3D Printing in Biomedical Research · Microfluidic and Bio-sensing Technologies · Innovative Microfluidic and Catalytic Techniques Innovation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Physics and GAEL, Georgetown University, NW Washington, DC 20057
Science Applications International Corporation 1710 SAIC Drive, McLean, Virginia 22102
Department of Pharmacology, Georgetown University, NW Washington, DC 20057
References (5)
Show source-provided references
1. Sensors Actuators A · 2003 · 104 · 19510.1016/S0924-4247(03)00049-9 ↗
2. J. Micromech. Microeng. · 2001 · 11 · 53210.1088/0960-1317/11/5/314 ↗
3. Sens. Actuators B · 1998 · 48 · 35610.1016/S0925-4005(98)00071-9 ↗
4. Appl. Phys. Lett. · 1996 · 68 · 32210.1063/1.116073 ↗
5. J. Vac. Sci. Technol. B · 1999 · 17 · 250710.1116/1.591119 ↗