Temperature distribution over a GaAs heterojunction bipolar transistor measured by fluorescent microthermal imaging
Source abstract
Abstract
Fluorescent microthermal imaging (FMI) is used to measure the temperature at the surface of a 2×2 μm2 heterojunction bipolar transistor. The presence of an artifact at the emitter post indicates that accurate temperature measurements are limited to flat surfaces. The FMI measurements obtained for various power dissipations are compared with electrical measurements of the junction temperature. The good agreement between the two techniques suggests that the temperature drop along the emitter post of the device is within a few degrees.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Thermal properties of materials · Machine Learning in Materials Science · Thermography and Photoacoustic Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Nortel Networks, 3500 Carling Avenue, Nepean, Ontario, Canada
Ecole Polytechnique de Montréal, Quebec, Canada
References (3)
Show source-provided references
1. IEEE Trans. Electron Devices · 1992 · 39 · 223510.1109/16.158793 ↗
2. Appl. Phys. Lett. · 1982 · 40 · 78210.1063/1.93258 ↗
3. Appl. Phys. Lett. · 1983 · 42 · 11710.1063/1.93766 ↗