Tip-induced deformation of polystyrene latex reference nanoparticles in atomic force microscopy
Source abstract
Abstract
The measurement approach typically prescribed for sizing polystyrene latex (PSL) reference nanoparticles by atomic force microscopy (AFM) is based on a single value of the height obtained from a three-dimensional image of the particle. A major challenge is that PSLs reportedly deform during sample preparation as well as imaging. While the particle-substrate deformation is controlled by adhesive contact forces, the tip-induced deformation may vary to a large degree depending on the operational conditions and the geometrical constraints imposed by the instrument. In this paper, the authors are mainly concerned with the effect of cantilever tilt, tip shape, and setpoint voltage on tip-induced deformation of PSL reference nanoparticles. Tips are characterized by scanning electron microscopy and using a multilayer Si/SiO2 tip characterizer. The authors find that the plastic flow of materials, induced by the asymmetric imaging geometry, shifts the position of the maximum particle height away from the center. This shape-change often leads to an initial height increase for PSLs that are smaller than 40 nm. Since AFM height analysis algorithms often equate apparent particle height with the highest measured point of the particle, these results have implications from the perspective of AFM-based nanoparticle metrology.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Force Microscopy Techniques and Applications · Near-Field Optical Microscopy · Surface Roughness and Optical Measurements
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Theiss Research 1 , 7411 Eads Ave., La Jolla, California 92037
National Institute of Standards and Technology 2 , Gaithersburg, Maryland 20899
References (17)
Show source-provided references
1. Colloids Surf. A · 1999 · 153 · 46710.1016/S0927-7757(98)00535-4 ↗
2. Aerosol Air Qual. Res. · 2010 · 10 · 12510.4209/aaqr.2009.10.0062 ↗
3. J. Nanopart. Res. · 2000 · 2 · 510.1023/A:1010053806769 ↗
4. Meas. Sci. Technol. · 2011 · 22 · 09400110.1088/0957-0233/22/9/094001 ↗
5. Proc. SPIE · 2012 · 8378 · 83780G10.1117/12.921451 ↗
6. J. Appl. Phys. · 2016 · 119 · 21430710.1063/1.4953210 ↗
7. 201610.6028/NIST.SP.260-185 ↗
8. 2007
9. J. Micro/Nanolithogr. MEMS MOEMS · 2011 · 10 · 01301510.1117/1.3549914 ↗
10. Metrologia · 2003 · 40 · 0400110.1088/0026-1394/40/1A/04001 ↗
11. Langmuir · 2004 · 20 · 276010.1021/la036128m ↗
12. J. Appl. Phys. · 2008 · 103 · 06451310.1063/1.2885734 ↗
13. Rev. Sci. Instrum. · 2017 · 88 · 12371010.1063/1.4986201 ↗
14. Langmuir · 2013 · 29 · 133310.1021/la304280h ↗
15. Rev. Sci. Instrum. · 2006 · 77 · 10370410.1063/1.2356855 ↗
16. e-J. Surf. Sci. Nanotechnol. · 2011 · 9 · 29310.1380/ejssnt.2011.293 ↗
17. Ultramicroscopy · 2005 · 102 · 16110.1016/j.ultramic.2004.09.009 ↗