Optimization of closed ion source for a high-sensitivity residual gas analyzer
Source abstract
Abstract
A closed ion source (CIS) has been optimized by investigating the effect of electron entrance slit size and the effect of mesh in the slit. A stainless steel mesh was placed on the electron entrance slits for a uniform potential distribution inside the CIS anode. Sensitivity of the closed ion sources having four different slit sizes with and without the mesh was compared using mass spectra of SF6 gas (97% He gas base) introduced into the CIS anode through a needle valve. For each CIS, isolation of anode potential with a mesh in the slit exhibited a significant sensitivity enhancement, but ion current measured directly behind each CIS showed negligible mesh effect. In order to elucidate the mesh effect, electron trajectories were simulated inside the anode. The computer simulation shows that, with mesh in the slit, more electrons are focused to a central region of the anode. This suggests ions generated in the CIS with mesh should have higher probability of passing through the quadrupole mass filter.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Mass Spectrometry Techniques and Applications · Nuclear Physics and Applications · Gas Sensing Nanomaterials and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Korea Research of Institute Standards and Science , Daejeon 305-340, Republic of Korea
References (18)
Show source-provided references
1. J. Vac. Sci. Technol. A · 1997 · 15 · 131210.1116/1.580582 ↗
2. J. Mass Spectrom. · 2000 · 35 · 65910.1002/1096-9888(200006)35:6<659::AID-JMS5>3.0.CO;2-V ↗
3. McDowell · 1963
4. Rev. Sci. Instrum. · 2005 · 76 · 04410110.1063/1.1889447 ↗
5. Rev. Sci. Instrum. · 2006 · 77 · 08510710.1063/1.2336756 ↗
6. Rev. Mod. Phys. · 1966 · 38 · 110.1103/RevModPhys.38.1 ↗
7. J. Chem. Phys. · 1980 · 73 · 376310.1063/1.440606 ↗
8. Mass Spectrom. Rev. · 1996 · 15 · 24110.1002/(SICI)1098-2787(1996)15:4<241::AID-MAS2>3.0.CO;2-I ↗
9. Vacuum · 2009 · 83 · S26010.1016/j.vacuum.2009.01.077 ↗
10. J. Vac. Sci. Technol. A · 2007 · 25 · 16710.1116/1.2364001 ↗
11. R. E. Ellefson and l. C. Frees, U.S. patent US2005/0258374 A1 (2005).
12. C. Yang, J. P. Merrill, L. C. Frees, and S. J. Lakeman, U.S. patent US2009/0014644 A1 (2009).
13. Rev. Sci. Instrum. · 1998 · 69 · 200010.1063/1.1148888 ↗
14. Int. J. Mass Spectrom. · 2010 · 294 · 3310.1016/j.ijms.2010.05.001 ↗
15. J. Appl. Phys. · 1986 · 59 · 179010.1063/1.336401 ↗
16. V. Katsap, J. A. Liddle, and W. K. Waskiewicz, US patent 6232040 B1 (2001).
17. C. J. Park and S. W. Yoon, US patent 7453061 B2 (2008).
18. Rev. Sci. Instrum. · 2008 · 79 · 09510710.1063/1.2981691 ↗