journal article·2007-03-01

Inverted-magnetron cold-cathode gauge in hybrid-discharge mode

Huiyong Mao, Yi Wang

Publisher page

Abstract

In high-vacuum measurement, cold-cathode ionization gauges have been widely used due to their unique advantages such as being simple and robust, low outgassing, x-ray effects, and so on. But during the measuring process, they show that a considerable pump effect, contamination buildup, and the heating and sputtering of the electrode surface from discharge can also become a serious problem at higher measured pressures. In such circumstances, pulsed operation is a good solution. However, the lowest measurable pressure of cold-cathode ionization gauges in pulsed operation is hard to extend, which limits its application. But if the measurable range of the cold-cathode gauge is divided into two regions, the low-pressure region where it is operated in dc discharge mode to ensure its lowest measurable pressure and the high-pressure region where it is operated in pulsed-discharge mode to reduce its above disadvantages at high pressures, the problem can be well solved. This article describes a pulsed high-voltage generating circuit controlled by a single-chip CPU to perform such a hybrid discharge in an inverted-magnetron gauge. With this circuit, the following problems of an inverted-magnetron gauge were investigated: the difference between pulsed-discharged mode and dc discharge mode, one method of extending the low measurable pressure limit in pulsed-discharge mode, the volt-current characteristics at different pressures, and constant-current pulsed-discharge measurement at pressures above 2×10−2Pa.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Sensor Technology and Measurement Systems · Advanced Sensor Technologies Research · High voltage insulation and dielectric phenomena

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Beijing Jiaotong University School of Electrical Engineering, , 100044 Beijing, China

References (19)

Show source-provided references
1. Philips Tech. Rev. · 1937 · 2 · 201
2. Vacuum · 1952 · 2 · 13710.1016/0042-207X(52)90458-2 ↗
3. Vacuum · 1953 · 3 · 2410.1016/0042-207X(53)93785-3 ↗
4. Can. J. Phys. · 1958 · 36 · 25510.1139/p58-030 ↗
5. Can. J. Phys. · 1958 · 36 · 27110.1139/p58-031 ↗
6. Can. J. Phys. · 1959 · 37 · 126010.1139/p59-144 ↗
7. J. Appl. Phys. · 1961 · 32 · 261910.1063/1.1728362 ↗
8. Jpn. J. Appl. Phys., Suppl. · 1974 · 2 · 10910.1143/JJAP.13.109 ↗
9. J. Appl. Phys. · 1984 · 55 · 72310.1063/1.333130 ↗
10. J. Vac. Sci. Technol. A · 1988 · 6 · 114110.1116/1.575662 ↗
11. J. Vac. Sci. Technol. A · 1990 · 8 · 280610.1116/1.576629 ↗
12. J. Vac. Sci. Technol. A · 1991 · 9 · 197710.1116/1.577439 ↗
13. J. Vac. Sci. Technol. A · 1996 · 14 · 129210.1116/1.579944 ↗
14. J. Vac. Sci. Technol. A · 1997 · 15 · 74010.1116/1.580813 ↗
15. J. Vac. Sci. Technol. A · 1999 · 17 · 204110.1116/1.581912 ↗
16. J. Vac. Sci. Technol. A · 2000 · 18 · 172410.1116/1.582479 ↗
17. J. Vac. Sci. Technol. A · 2003 · 21 · 93710.1116/1.1578654 ↗
18. Vacuum · 2003 · 71 · 22510.1016/S0042-207X(02)00741-8 ↗
19. Vacuum · 2004 · 73 · 28110.1016/j.vacuum.2003.12.008 ↗