Measurements of spatial and temporal sheath evolution inside tubular material for inner surface ion implantation
Source abstract
Abstract
Tubular target of aluminum (inner radius=5 cm, length=15 cm) was immersed in a nitrogen plasma with plasma densities of 6.8×109–5×1010 cm−3 and biased negatively (10–30 kV). A Langmuir probe was used to detect the propagating sheath edge. A comparison of experiment measurements and numerical calculations of temporal and spatial sheath evolution is presented. Experiment measurements of sheath edge position were in good agreement with those determined by numerical calculations.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Ion-surface interactions and analysis · Plasma Diagnostics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Group 101, Institute of Physics, Chinese Academy of Sciences, Beijing 100080, Peoples Republic of China
References