Influence of electron diffusion on the cathode sheath of a magnetron discharge
Source abstract
Abstract
This article describes the theory and numerical modeling of the cathode sheath region near the target of a magnetron. Since electrons are assumed to be confined by the magnetic field, a fluid model is appropriate. Collisionless and fluid models for ion motion are considered and the sheath properties are compared for each of the models considered. It is shown that, if electron diffusion in the sheath is classical, the magnetized electrons have a strong effect on the sheath, whereas for the case of Bohm diffusion this effect is negligible.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Plasma Diagnostics and Applications · Aerosol Filtration and Electrostatic Precipitation · High voltage insulation and dielectric phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Research Institute for Design, Manufacture and Marketing, Salford University, Salford M5 4WT, United Kingdom
References
Reference metadata was not supplied for this record.