journal article·1988-05-01

Helium cryopumping for fusion applications

D. W. Sedgley, T. H. Batzer, W. R. Call

Publisher page

Abstract

Large quantities of helium and hydrogen isotopes will be exhausted continuously from fusion power reactors. This paper summarizes two development programs undertaken to address vacuum pumping for this application: (i) A continuous duty cryopump for pumping helium and/or hydrogen species using charcoal sorbent and (ii) a cryopump configuration with an alternative shielding arrangement using charcoal sorbent or argon spray. A test program evaluated automatic pumping of helium, helium pumping by charcoal cryosorption and with argon spray, and cryosorption of helium/hydrogen mixtures. The continuous duty cryopump pumped helium continuously and conveniently. Helium pumping speed was 7.7 l/s/cm2 of charcoal, compared to 5.8 l/s/cm2 for the alternative pump. Helium speed using argon spray was 18% of that obtained by charcoal cryosorption in the same (W-panel) pump. During continuous duty cryopump mixture tests with helium and hydrogen copumped on charcoal, gas was released sporadically. Testing was insufficient to explain this unacceptable event.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Superconducting Materials and Applications · Particle accelerators and beam dynamics · Fusion materials and technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Grumman Corporation, Bethpage, New York 11714

Lawrence Livermore National Laboratory, Livermore, California 94550

References

Reference metadata was not supplied for this record.