Poly-Si etching using electron cyclotron resonance microwave plasma sources with multipole confinement
Source abstract
Abstract
In this study, mirror field and single coil 2.45 GHz electron cyclotron resonance microwave plasma sources were coupled to a multipole, multicusp plasma confinement system and used to produce chlorine plasmas for poly-Si etching. Scanning Langmuir probes were used to study the effect of process parameters on plasma potentials, plasma density, plasma density uniformity, and electron temperature, while poly-Si etching experiments on 150 mm diam wafers were used to relate process parameters and Langmuir probe results to etch rate, SiO2 selectivity, photoresist selectivity, and etch uniformity. Radio-frequency substrate bias at 13.56 MHz was used for ion energy control, and the addition of a third coil below the substrate plane was found useful for fine-tuning the radial plasma uniformity. Undoped poly-Si etch rates ≳3000 Å/min, Si/SiO2 etch selectivities ≳25 and 150 mm diam etch uniformities <2% at 1 σ were obtained, but not simultaneously. Tradeoffs in choosing operating conditions for optimum poly-Si etch performance will be discussed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Plasma Diagnostics and Applications · Copper Interconnects and Reliability · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
SEMATECH, Austin, Texas 78741
References
Reference metadata was not supplied for this record.