The vacuum system for a British long baseline gravitational wave detector
Source abstract
Abstract
A description is given of the vacuum system for a 1×1 km long optical interferometric gravitational wave detector. The vacuum chamber consists of two tubes, 900-mm diameter, 1 km long, joined together in the shape of an L. End tanks ∼3-m diameter ∼3 m long contain the optical equipment. The tubes will be heated to 150 °C to reach outgassing rates of ∼10−12 Torr l/s/cm2 and pumped by turbomolecular pumps at 500-m intervals to obtain a pressure of ∼10−8 Torr. A significant cost saving is achieved by using thin-walled corrugated stainless-steel tube. The sensitivity of the detector is governed, among other things, by fluctuation in the vacuum pressure. Some discussion of the possible causes of these fluctuations is given.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Pulsars and Gravitational Waves Research · Numerical methods for differential equations · Advanced Measurement and Metrology Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Rutherford Appleton Laboratory, Science and Engineering Research Council, Chilton, Didcot, Oxfordshire, OX11 OQX, England