Fire and flame retardants for PVC

A. William Coaker

Publisher page

Abstract

Abstract The flammability performance of PVC plays a significant role in its selection for many applications. Its relatively high chlorine content (56.8%) makes it more resistant to ignition and burning than most organic polymers. In the case of flexible PVC, the plasticizers that contribute flexibility in most instances detract from its resistance to fire. To meet specifications such as oxygen index, heat release, smoke evolution, or extent of burning in cable tests, flame‐retardant (FR) and smoke‐suppressant (SS) additives are often incorporated. Synergistic combinations of FR and SS additives help PVC formulations meet many stringent FR specifications cost effectively.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Flame retardant materials and properties · Polymer Science and PVC · Environmental and Industrial Safety

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Bulletin G‐62RES Geon Vinyl Resin Material Safety Data BF Goodrich Chemical Group: January1985.
2. Coaker A. W. · 2000 · 125
3. Brookman R. S. · B34
4. Private communication.
5. Morley J. C. · 1993 · 551
6. D. D.Drysdale Society of Fire Protection Engineers Handbook of Fire Protection Engineering P. J. DiNenno ed. Boston and Quincy MA; SFPE and NFPA pp.1–149(1988).
7. 1989
8. 10.1021/ma60071a00110.1021/ma60071a001 ↗
9. W. H.Starnes Jr. Annual Report of the Center for Fire Research of the National Bureau of Standards 66(1987) (renamed the National Institute of Standards and Technology).
10. W. H.Starnes Jr. et al. “Smoke Suppression of PVC by Reductive Crosslinking ” at Additives '98 Conference in Orlando FL. February (1998).
11. 10.1016/0165-2370(85)80023-110.1016/0165-2370(85)80023-1 ↗
12. 2002 National Fire Protection Association Inc. Quincy MA
13. “Vertical Tray Flame Test ” inReferences Standard for Electrical Wires Cables and Flexible Cords ANSI/UL 1581–1991 UL Northbrook IL.
14. “CSA Vertical Flame Test for Cables in Cable Trays ”CSA 22.2 No. 0.3‐M‐1985 Test Methods for Electrical Wires and Cables Canadian Standards Association.
15. A. W.CoakerandC. H.McMullen “PVC—the Preferred Choice for Indoor Wire and Cable ” 9th Annual Wire and Cable Focus Conference Providence Rhode Island September 18–20 (2000).
16. NFPA
17. M. M.Hirschler Comment 16–98 NEC Committee Report on Comments May 14–17 2001 NFPA Technical Meeting Anaheim CA National Fire Protection Association Quincy MA p.592(2001).
18. ANSI/UL1666–1997 Standard Test for Flame Propagation Height of Electrical and Optical‐Fiber Cable Installed Vertically in Shafts UL Northbrook IL.
19. VW‐1 Flame Test in ANSI/UL 1581–1991 Reference Standard for Electrical Wires Cables and Flexible Cords UL Northbrook IL.
20. “Using Reofos in PVC ” Bulletin from Great Lakes Chemical Corporation West Lafayette Indiana.
21. Touchette N. W. · 1993 · 275
22. Advice on use of antimony oxide and FR plasticizers is available from Great Lakes Chemical Corporation. West Lafayette Indiana; advice on ALT is provided by Alcoa Industrial Chemicals of Bauxite Arkansas and Alusuisse USA Fairlawn New Jersey; advice on zinc borate is available from U.S. Borax Inc. of Valencia California.
23. H.Naseem United States Patent #4 892 683 (1990).
24. Walker J. K.
25. 10.1002/vnl.1025110.1002/vnl.10251 ↗
26. American Chemistry CouncilBFRIP Workshop Arlington Virginia Nov. 13 2001.
27. R. C.AndersonandS.Kaufman International Wire and Cable Symposium Proceedings Reno Nevada p.636(1988).
28. Federal Register Vol. 36 No 232 Title 49 Transportation #521.302 (1972).
29. R. D.Pike W. H.Starnes et al. Proceedings of 13th Annual BCC Conference on Flame Retardancy Stamford CT June2002.