Can lead content be measured by handheld X‐ray fluorescence spectroscopy to meet REACH regulation?
Source abstract
Abstract
Abstract Lead compounds have long been the most commonly used stabilizers for PVC products, but they are classified as toxic to reproduction category 1A, and their use is restricted in Europe. To promote recycling, the European Union adopted Regulation (EU) 2023/923, which permits the use of recycled rigid PVC (PVC‐U) containing up to 1.5% w/w of lead in specific products. This study compares the results obtained from two different handheld X‐Ray Fluorescence (HHXRF) devices on samples with known composition, also considering the matrix effect. This kind of evaluation is still missing in the literature. The measurements from both HHXRF devices show that the lead content falls within the 13% of relative inaccuracy range specified for lead in IEC 62321‐3‐1:2013, the standard currently used for determining lead in electrotechnical products. To assess whether the matrix effect can influence the measurements, two samples were produced by altering only the content of titanium dioxide. The results from both instruments were not significantly different, considering the 13% inaccuracy. In conclusion, HHXRF could be an effective method to determine the lead concentration in its usual dosage in the PVC‐U matrix. In case of inconclusive results based on this range, it is recommended to analyze the sample with another, more accurate technique, such as ICP. Highlights Statistical evaluation of accuracy of lead in samples with known composition. Evaluation of significant excess legal concentration. Prove infringements with fast and massive checks.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Heavy Metal Exposure and Toxicity · Recycling and Waste Management Techniques · Analytical chemistry methods development
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Reagens S.p.A. San Giorgio di Piano Italy
Department of Economics University of Bologna Bologna Italy
National Institute of Health in Italy Viale Regina Elena Rome Italy
References (39)
Show source-provided references
1. VinylPlus.Progress Report.2016https://vinylplus.eu/wp-content/uploads/2021/06/160826_VINYPLUS_2016_WEB_PS_Singlepage_version-1.pdf
2. European Commission.Regulation (EU) 2023/923 of 3 May 2023 amending Annex XVII to Regulation (EC) No 1907/2006 of the European Parliament and of the Council as regards lead and its compounds in PVC.2023https://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX:32023R0923
3. European Chemicals Agency.Compendium of Analytical Methods recommended by the Forum to check compliance of REACH Annex XVII restrictions.2021https://echa.europa.eu/documents/10162/17088/compendium_of_analytical_methods_en+%281%29.pdf/4c730fb9‐1b48‐2e14‐6ee3‐7a36391b7322?t=1626370365832
4. 10.3139/978156990544910.3139/9781569905449 ↗
5. European Chemicals Agency RAC‐SEAC.Opinion on an Annex XV dossier proposing restrictions on Lead Stabilizers in PVC.2018https://echa.europa.eu/documents/10162/86b00b9e-2852-d8d4-5fd7-be1e747ad7fa
6. BernaM.Convegno Nazionale AIM Catania Italy Sept. 9‐12 2018.
7. EuCertPlast.Audit Scheme Version 4. 2. 2021.https://www.eucertplast.eu/_files/ugd/dda42a_8bf875a39baa44b4a019bf6d966595fa.pdf
8. European Commission CORDIS – EU research results.https://cordis.europa.eu/article/id/36171‐a‐mark‐of‐trust‐for‐plastics‐recyclers.
9. EN 15343:2008 Plastics–Recycled Plastics – Plastics recycling traceability and assessment of conformity and recycled content European Standards Plzen Czech Republic.2008https://www.en‐standard.eu/une‐en‐15343‐2008‐plastics‐recycled‐plastics‐plastics‐recycling‐traceability‐and‐assessment‐of‐conformity‐and‐recycled‐content/
10. VinylPlus.Progress Report.2023https://www.vinylplus.eu/wp‐content/uploads/2023/07/VinylPlus_ProgressReport_Digital_2023.pdf
11. ISO 868 Plastics and ebonite.Determination of indentation hardness by means of a durometer (shore hardness). International Organization for Standardization;2003https://www.iso.org/standard/34804.html
12. ASTM 2240–15 · 2015
13. 10.1080/1040834989119420710.1080/10408349891194207 ↗
14. IEC 62321‐3‐1:2013 · 2013
15. IEC 62321‐5:2013.Determination of certain substances in electrotechnical products – Part 5: Cadmium lead and chromium in polymers and electronics and cadmium and lead in metals by AAS AFS ICP‐OES and ICP‐MS International Electotechnical Commission Geneva Switzerland.2013https://webstore.iec.ch/en/publication/6833
16. ASTM F 2617:2015 · 2015
17. CPSC‐CH‐El 002‐08.Standard Operating Procedure for Determining Total Lead (Pb) in Non‐Metal Children's Products Consumer Product Safety Commission Bethesda MD 20814 USA.2009https://www.cpsc.gov/s3fs-public/pdfs/blk_pdf_CPSC-CH-E1002-08.pdf
18. MennenMG vanPuttenEM FortezzaF van deBeekACW vanVeen enJ vanDijkRPM.Oriënterend onderzoek naar zware metalen in verpakkingen. Onderzoek ten behoeve van de Handhaving van de Regeling verpakkingen. RIVM Rapport 609021022/2002 RIVM. 2002.https://rivm.openrepository.com/bitstream/handle/10029/9241/609021022.pdf;jsessionid=0823FCAA71412D8AAE43073D3A53644C?sequence=1
19. Bruker online https://www.bruker.com/en/products-and-solutions/elemental-analyzers/handheld-xrf-spectrometers/S1-TITAN.html.
20. Olympus online.https://www.olympus-ims.com/it/delta-premium/#!cms[focus]=cmsContent11675.
21. Hitachi online https://hha.hitachi-hightech.com/en/pages/handheld-xrf-analyzer.
22. Spectro online https://www.spectro.com/products/xrf-handheld-analyzer/xsort-xhh03
23. ThermoFisher Scientific https://www.thermofisher.com/order/catalog/product/XL2
24. 10.1016/j.talanta.2023.12550010.1016/j.talanta.2023.125500 ↗
25. 10.1016/j.forc.2023.10051510.1016/j.forc.2023.100515 ↗
26. ICP‐AES method for analysis of complex thermal stabilizer for PVC
27. Determination of lead, cadmium, chromium, mercury in PVC and its products by low pressure microwave‐assisted closed digestion ‐ICP‐AES
28. 10.2116/analsci.29.23910.2116/analsci.29.239 ↗
29. Analysis of Pb, Cd, Cr, Hg in PVC from mechanical and electrical products by DUO‐ICP‐AES with the technology of pressurized digestion
30. Rapid analysis of harmful elements for food contact plastics using microwave digestion and ICP‐MS
31. PiorekS.Portable X‐ray fluorescence analyzer for the first level screening of materials for prohibited substances. Proceedings of [the] International Conference on Asian Green Electronics: Design for Manufacturability and Reliability Shanghai China. 7‐13.2005.10.1109/AGEC.2005.1452307 ↗
32. GearhartJ PosseltH PatelM.X‐ray Fluorescence Spectroscopy (XRF) as a public health screening tool for the presence of hazardous chemicals in plastics. GPEC 2009 Global Plastics Environmental Conference Orlando FL United States Feb. 25‐27 2009 gearh1/1‐gearh1/7.
33. Hazardous metals in vintage plastic toys measured by a handheld X‐ray fluorescence spectrometer
34. 10.1017/S001675681900018910.1017/S0016756819000189 ↗
35. 10.1007/s11356‐022‐19751‐510.1007/s11356‐022‐19751‐5 ↗
36. Lead measurement in PVC plastic by x‐ray fluorescent analysis
37. 10.1154/1.273746510.1154/1.2737465 ↗
38. Comparison of X‐ray fluorescence spectrometry to traditional analytical methods for elemental determination in polymeric materials
39. KochR Hubbard‐NelsonB RussellK SackettD.Annual Technical Conference – Society of Plastics Engineers; 2343–2347.2005.