Simplified calculation model for typical Dou-gong under horizontal load
Source abstract
Abstract
Abstract Dou-gong is important component of ancient timber buildings in China, Japan, and South Korea, etc. It has important decoration and load transferring functions. Due to its complex structure, Dou-gong is difficult to be fully analyzed in large-scale structured. Therefore, it is necessary to establish a reliable and simplified Dou-gong calculation model. In this study, some traditional Chinese timber buildings built in the Song and Yuan dynasties (960–1368 AD) are investigated, and the characteristics of the typical Dou-gong model are obtained. Experimental study and refined finite-element analysis of the typical Dou-gong model is then carried out to study the load transferring mechanism under horizontal load. Then, the load path is extracted from the force-flow perspective to establish a simplified beam element model. The simplified model is then numerically and experimentally verified. The results show that the simplified model has a good consistency with the experimental model, and it is suitable for large-scale structural analysis of ancient timber buildings.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Remote Sensing and Land Use · Tree Root and Stability Studies · Simulation and Modeling Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Wu YJ, Song XB, Li K (2018) Compressive and racking performance of eccentrically aligned Dou-gong connections. Eng Struct 175:743–75210.1016/j.engstruct.2018.08.054 ↗
2. Chen Z, Zhu E, Lam F, Pan J (2014) Structural performance of Dou-Gong brackets of Yingxian Wood Pagoda under vertical load—an experimental study. Eng Struct 80:274–28810.1016/j.engstruct.2014.09.013 ↗
3. Wu C, Xue J, Song D, Ren G, Zhang J (2022) Mechanical performance of inclined Dougong bracket sets under vertical load : experimental tests and finite element calculation. J Build Eng 45:10355510.1016/j.jobe.2021.103555 ↗
4. Cao J, Zhao Y, Liu Y, Lu H, Wang W (2021) Load-carrying capacity analysis of traditional Chinese Dou-gong joints under monotonic vertical and reversal lateral loading. J Build Eng 44:10284710.1016/j.jobe.2021.102847 ↗
5. Meng X, Li T, Yang Q (2019) Lateral structural performance of column frame layer and Dou-Gong layer in a timber structure. Ksce J Civ Eng 23:666–67710.1007/s12205-018-0259-4 ↗
6. Sha B, Xie L, Yong X, Li A (2021) Hysteretic behavior of an ancient Chinese multi-layer timber substructure : a full-scale experimental test and analytical model. J Build Eng 43:10316310.1016/j.jobe.2021.103163 ↗
7. Sui Y, Zhao HT, Xue JY, Zhang XC (2012) Experimental study on stiffness of Dougong in Chinese ancient buildings. 4th International Conference on Technology of Architecture and Structure (ICTAS 2011)
8. Wu C, Xue J, Song D, Zhang Y (2022) Seismic performance evaluation of a roof structure of a historic Chinese timber frame building. Int J Arch Herit 16:1474–149510.1080/15583058.2021.1894503 ↗
9. Xie Q, Wang L, Zhang L, Xiang W, Hu W (2020) Rotational behaviors of fork-column Dou-Gong : experimental tests and hysteresis model. J Perform Constr Fac 34:0402003210.1061/(ASCE)CF.1943-5509.0001426 ↗
10. Wu Y, Song X, Gu X (2020) Lateral load-displacement model of Dou-Gong connections based on rocking and racking coordination. J Build Struct 43:197–202+211
11. Wang M, Xu Q, Zhou Q, Chen X, Leng Y, Zhang F (2021) Analysis on hysteretic performance of Dou-Gong connection based on three dimensional elastic-plastic damage evolution. Build Struct 51:103–108+113
12. Fang DP, Iwasaki S, Yu MH, Shen QP, Miyamoto Y, Hikosaka H (2001) Ancient Chinese timber architecture. II : dynamic characteristics. J Struct Eng 127:1358–136410.1061/(ASCE)0733-9445(2001)127:11(1358) ↗
13. Wu C, Xue J, Zhang X, Bai F, Ma H (2023) Seismic assessment and fragility analysis of traditional Chinese timber frame building considering degraded connections. Int J Arch Herit 17:553–57210.1080/15583058.2021.1949507 ↗
14. Wu C, Xue J, Zhou S, Zhang F (2021) Seismic performance evaluation for a traditional Chinese timber-frame structure. Int J Arch Herit 15:1842–185610.1080/15583058.2020.1731626 ↗
15. Wu C, Zhang X, Xue J, Ma H, Wu J (2022) Effect of performance degradation and infilled walls on seismic fragility assessment of traditional Chinese timber-frame structure. Int J Arch Herit 16:1252–126910.1080/15583058.2021.1879311 ↗
16. Li Y, Deng Y, Li A (2021) Simplified simulation method for hysteretic behavior of wood brackets. J Perform Constr Fac 35:0402108510.1061/(ASCE)CF.1943-5509.0001665 ↗
17. Li J (1954) Ying-tsao-fa-shi. Commercial Press, Shanghai
18. Ministry of Housing and Urban-Rural Construction of the People’s Republic of China (2019) Load code for the design of building structures. China Architecture and Building Press, Beijing
19. Chun Q, Meng Z, Han Y (2017) Research on mechanical properties of main joints of Chinese traditional timber buildings with the type of post-and-lintel construction. Int J Archit Herit 11:247–26010.1080/15583058.2016.1204487 ↗
20. Kelly DW, Hsu P, Asudullah M (2001) Load paths and load flow in finite element analysis. Eng Comput 18:304–31310.1108/02644400110365923 ↗
21. Li S, Xin Y, Yu Y, Wang Y (2021) Design for additive manufacturing: a force-flow perspective. Mater Des 204:10966410.1016/j.matdes.2021.109664 ↗
22. Kwok TH, Li Y, Chen Y (2016) A structural topology design method based on principal stress line. Comput Aid Design 80:19–3110.1016/j.cad.2016.07.005 ↗
23. Ogawa K, Sasaki Y, Yamasaki M (2015) Theoretical modeling and experimental study of Japanese “Watari-ago” joints. J Wood Sci 61:481–49110.1007/s10086-015-1498-3 ↗
24. Cheng X, Shen B, Liu W, Lu W (2019) Experimental study on mechanical properties of Song-style Dougong joints with Ang. J Build Struct 40:133–142