Thermography measurements and latent heat documentation of Norwegian spruce (Picea abies) exposed to dynamic indoor climate
Source abstract
Abstract
Hygroscopic materials hold the potential to reduce ventilation loads in a building by damping the peak fluctuations of the indoor relative humidity. Of particular interest is the moisture buffer capacity of wooden surfaces. This paper investigates, the response of Norwegian spruce ( Picea abies ) samples to changes of indoor relative humidity as well as the corresponding latent heat release during moisture buffering. A climate chamber was used to subject samples to dynamic air humidity. Thermographic techniques and thermocouples were employed to measure surface temperature on the exposed surface of the spruce sample (permeable case), while a covered control sample was used as reference (impermeable case). The moisture uptake was logged synchronously by weighting cells. The results show that the surface temperature of spruce increased by 2.1 °C during moisture uptake, while only by 0.9 °C in the control sample. This finding has implications for direct energy savings when wooden surfaces are used indoors. In addition, thermography is evaluated as an appropriate measurement method for documenting latent heat release.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Hygrothermal properties of building materials · Wood Treatment and Properties · Urban Heat Island Mitigation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (10)
Show source-provided references
1. Simonson CJ, Salonvaara M, Ojanen T (2001) Improving indoor climate and comfort with wooden structures. VTT Publications 431, Technical Research Centre of Finland, Espoo
2. Osanyintola OF, Simonson CJ (2006) Moisture buffering capacity of hygroscopic building materials: experimental facilities and energy impact. Energy Build 38:1270–128210.1016/j.enbuild.2006.03.026 ↗
3. Rode C, Grau K (2008) Moisture buffering and its consequence in whole building hygrothermal modeling. J Build Phys 31:333–36010.1177/1744259108088960 ↗
4. Woloszyn M, Kalamees T, Abadie MO, Steeman M, Kalagasidis AS (2009) The effect of combining a relative-humidity-sensitive ventilation system with the moisture-buffering capacity of materials on indoor climate and energy efficiency of buildings. Build Environ 44:515–52410.1016/j.buildenv.2008.04.017 ↗
5. Rode C, Peuhkuri R, Mortensen LH, Hansen KK, Time B, Gustavsen A, Ojanen T, Ahonen J, Svennberg K, Harderup LE, Arfvidson J (2005) Moisture buffering of building materials. Project No.: 04023. Nordic Innovation Centre
6. Li Y, Fazio P, Rao J (2012) An investigation of moisture buffering performance of wood panelling at room level and its buffering effect on a test room. Build Environ 47:205–21610.1016/j.buildenv.2011.07.021 ↗
7. Mendes N, Winkelmann FC, Lamberts R, Philippi PC (2003) Moisture effects on conduction loads. Energy Build 35:631–64410.1016/S0378-7788(02)00171-8 ↗
8. Hameury S (2006) Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate. A numerical study. Build Environ 40:1400–141210.1016/j.buildenv.2004.10.017 ↗
9. Madding RP (1979) Thermographic instruments and systems. University of Wisconsin, Extension, Department of Engineering and Applied Sciences, Madison, Wisconsin
10. Toftum J (2004) Air movement—good or bad? International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby