journal article·2012-08Open access

Effective lateral resistance of timber–plywood–timber joints connected with nails

Okumu Gordon Wanyama, Kei Sawata, Takuro Hirai, Akio Koizumi, Yoshihisa Sasaki

Journal of Wood Science· Volume 58· Issue 4

Abstract

In this study, an experimental study was conducted on the nailed timber–plywood–timber joints extended from the standard wall–floor joints of wooden light frame constructions, where the bottom plates of shear walls are nailed to the floors consisting of joists and floor sheathings nailed to them. The principal conclusions are as follows: The allowable lateral resistance of the nailed timber–plywood–timber joints can roundly be estimated by neglecting the plywood panels if their densities are higher than those of the timber main-members and they are fastened effectively onto the timber main-members. The stiffness of the timber–plywood–timber joints is less than that of the control timber–timber joints, which is improved by increasing the number of nails used to fasten the plywood panels onto the timber main-members. The stiffness of the joints whose floor sheathings are glued onto the joists is equivalent to the control timber–timber joints. The timber–plywood–timber joints with appropriate specifications have greater energy capacity until the failure than that of the control timber–timber joints. This ensures their energy capacity, which is important in dynamic resistance, to be equivalent to the control timber–timber joints.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Structural Analysis of Composite Materials · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (10)

Show source-provided references
1. Notification No. 1541 of the Ministry of Land, Infrastructure, Transport and Tourism (in Japanese), October 15, 2001
2. Meng Q, Hirai T, Sawata K, Sasaki Y, Koizumi A, Uematsu T (2010) Effect of frictional force on lateral resistance of wall–floor joints of wooden light frame constructions (in Japanese). Mokuzai Gakkaishi 56:48–5410.2488/jwrs.56.48 ↗
3. Architectural Institute of Japan (2006) Standard for structural design of timber structures (in Japanese). Architectural Institute of Japan, Tokyo, pp 266–278, 367–376
4. Johnsson H, Lukaszewska E (2004) Nailed timber joints with a thick interlayer. In: Proceedings, 8th world conference on timber engineering, Lahti, pp 281–284
5. Blass HJ, Laskewitz B (2000) Load-carrying capacity of joints with dowel-type fasteners and interlayers. In: Proceedings, CIB-W18, Delft, paper 33-7-6
6. Dias AMPG, Lopes SMR, Van de Kuilen JWG, Cruz HMP (2007) Load-carrying capacity of timber-concrete joints with dowel-type fasteners. J Struct Eng 133:720–72710.1061/(ASCE)0733-9445(2007)133:5(720) ↗
7. Uematsu T, Kamata N, Katayama D, Sasaki T, Chiba T (2010) Development of wooden share wall with additional external insulation (in Japanese). In: Summaries of technical papers, annual meeting of the Architectural Institute of Japan: structure system, pp 321–322
8. Japanese Agricultural Standard for Dimension Lumber of Wooden Light Frame Construction (2010) Japanese Agricultural Standard Association, Tokyo
9. Japanese Agricultural Standard for Plywood (2008) Japanese Agricultural Standard Association, Tokyo
10. Japan 2X4 Home Builders Association (2002) Structural design guidelines for wood frame construction (in Japanese). Japan 2×4 Home Builders Association, Tokyo, pp 214–216