Bending performance of sugi cross-laminated timber (CLT) composed of different thickness laminae
Source abstract
Abstract
Abstract This study aims to examine the influence of lamina thickness on the bending performance of sugi cross-laminated timber (CLT). The lamina specimens measuring 20 mm, 30 mm and 40 mm thick × 115 mm wide, and the CLT specimens composed of 5-layer–5-ply of equally thick laminae with 20 mm-, 30 mm- and 40 mm-thick laminae, respectively, and 3-layer–3-ply with 40 mm-thick laminae for the outer layers and 20 mm-thick laminae for the inner layer were prepared. The Young’s modulus and shear modulus were measured by dynamic methods. The bending tests were conducted and the bending performances such as apparent bending Young’s modulus and bending strength were measured, and the failure behavior was observed. The results showed that the influence of lamina thickness on the bending strength and failure behavior of CLT was not clear. On the other hand, the shear modulus of the CLT specimens composed of 40 mm-thick laminae whose width-to-thickness ratio of the lamina in the transverse layer was less than 3.5 was small, indicating that the small width-to-thickness ratio of the lamina in the transverse layer influenced bending performance. Furthermore, it was considered that the bending Young’s modulus and bending strength of the CLT specimens could generally be estimated using the bending Young’s modulus and bending strength of the laminae specimens by composite theory under the conditions in this study.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Bamboo properties and applications · Natural Fiber Reinforced Composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Shibusawa T, Fujita K, Miyatake A, Shindo K, Hiramatsu Y, Nagao H, Idoh AK, Watanabe H, Nakajima S (2013) Out-of-plane bending performances of sugi CLT. Wood Ind 68:526–531
2. Hiramatsu Y, Miyatake A, Tamaki T, Shido K, Ido H, Nagao H, Harada M, Ogiso J (2017) Effect of layup and grade of lumber on bending Young’s modulus and bending strength of sugi (Cryptomeria japonica) cross laminated timber under in-plane loading. Bull FFPRI 16:213–224
3. Ido H, Nagao H, Harada M, Kato H, Ogiso J, Miyatake A (2016) Effects of the width and lay-up of sugi cross-laminated timber (CLT) on its dynamic and static elastic moduli, and tensile strength. J Wood Sci 62:101–108. https://doi.org/10.1007/s10086-015-1527-210.1007/s10086-015-1527-2 ↗
4. The Ministry of Agriculture, Forestry and Fisheries of Japan (2020) Japanese Agricultural Standards for CLT. The Ministry, Tokyo (in Japanese).
5. Notification No. 611 of the Ministry of Land, Infrastructure, Transport and Tourism, Apr. 1 (2016) Establishment of the technical standards required for safety on buildings and its structural parts using CLT panel structure design method. Ministry of Land, Infrastructure, Transport and Tourism, Tokyo (in Japanese).
6. Notification No. 1024 of the Ministry of Land, Infrastructure, Transport and Tourism, June 12 (2001) Establishment of special allowable unit stress and special material strength. Ministry of Land, Infrastructure, Transport and Tourism, Tokyo (in Japanese).
7. EN 16351–2021 of European Committee for Standardization National Members Mar. 3 (2021) Timber Structures Cross Laminated Timber-Requirements. European Committee for Standardization, Bruxelles, Belgium.
8. Liaison conference for promotion of CLT utilization (2021) New road map for promotion of CLT utilization. https://www.cas.go.jp/jp/seisaku/cltmadoguchi/pdf/r3_ hontai.pdf. Accessed 11 Oct 2024 (in Japanese).
9. Nakahara T, Miyatake A, Fujita K, Sonoda S (2017) Effects of thickness of laminae on strength properties of CLT under out-of-plane loading-In case of thin laminae. Summaries of technical papers of annual meeting Architectural institute of Japan (Chugoku), pp 95–96 (in Japanese).
10. Fujita K, Nozawa K, Watanabe Y, et al (2017) Effects of thickness of laminae on strength properties of CLT under out-of-plane loading-In case of thick laminae. Summaries of technical papers of annual meeting, Architectural institute of Japan (Chugoku), 31 August–3 September, pp 93–94 (in Japanese).
11. Ukyo S, Shindo K, Miyatake A (2019) Evaluation of rolling shear modulus and strength of Japanese cedar cross-laminated timber (CLT) laminae. J Wood Sci. 65:31. https://doi.org/10.1186/s10086-019-1810-810.1186/s10086-019-1810-8 ↗
12. Kawaai Y, Ishihara W, Takanashi R, Ohashi Y, Sawata K, Sasaki T (2023) Relationship between the ratio of thickness and rolling shear strength of Japanese larch lamina. Mokuzai Gakkaishi 69:134–139
13. Li M (2017) Evaluating rolling shear strength properties of cross-laminated timber by short-span bending tests and modified planar shear tests. J Wood Sci 63:331–337. https://doi.org/10.1007/s10086-017-1631-610.1007/s10086-017-1631-6 ↗
14. O’Ceallaigh C, Sikora K, Harte AM (2018) The influence of panel lay-up on the characteristic bending and rolling shear strength of CLT. Buildings. https://doi.org/10.3390/buildings809011410.3390/buildings8090114 ↗
15. Sikora KS, Mcpolin DO, Harte AM (2016) Effects of the thickness of cross-laminated timber (CLT) panels made from Irish Sitka spruce on mechanical performance in bending and shear. Constr Build Mater 116:141–15010.1016/j.conbuildmat.2016.04.145 ↗
16. He M, Sun X, Li Z, Feng W (2020) Bending, shear, and compressive properties of three- and five-layer cross-laminated timber fabricated with black spruce. J Wood Sci. 66:38. https://doi.org/10.1186/s10086-020-01886-z10.1186/s10086-020-01886-z ↗
17. Navaratnam S, Christopher PB, Ngo T, Le TV (2020) Bending and shear performance of Australian Radiata pine cross-laminated timber. Constr Build Mater. 232:117215. https://doi.org/10.1016/j.conbuildmat.2019.11721510.1016/j.conbuildmat.2019.117215 ↗
18. Matsumoto T (1962) Studies on the dynamic modulus E and the logarithmic decrement of wood by transverse vibration. Bull Kyusyu Univ For 36:1–86. https://doi.org/10.15017/14991(inJapanese)10.15017/14991(inJapanese) ↗
19. Kubojima Y, Yoshihara H, Ohta M, Okano K (1996) Examination of the method of measuring the shear modulus of wood baced on the Timoshenko theory of bending. Mokuzai Gakkaishi 42:1170–1176
20. Horioka K (1956) Research for the improvement of wood (Rep. No.6) study on the properties of wood with special reference to its adhesion. Bull FFPRI 89:105–172
21. Takahashi T, Nakayama Y (1995) Wood science series 3 physics, 2nd edn. Kaiseisha Press, Shiga
22. Nakagawa M, Hiramatsu Y, Shindo K, Ohki F, Miyatake A (2024) Effects of lumber thickness and loaded face on bending performances of sugi. Wood Industry 79:92–98
23. The Japan Wood Research Society (1985) Wood Science Experiment Book I. Physics・Engineering, Tokyo, Japan (in Japanese).
24. EN1995–1–1 of European Committee for standardization National Members Nov. 1 (2004) Design of timber structures-General-Common rules and rules for buildings. European Committee for standardization, Bruxelles, Belgium.
25. Popovsk M, Gagnon S, Mohammad M, Chen Z (2019) Structural design of cross-laminated timber elements. In: Karacabeyli E, Gagnon S (eds) Canadian CLT handbook. FPInovations, Canada