Geometric Artifacts in Time‐of‐Flight Mobility Measurements of Perovskite Single Crystals
Source abstract
Abstract
ABSTRACT Carrier mobility is an important parameter of metal halide perovskites that determines carrier diffusion length in solar cells, response speed of detectors, and other device characteristics. Time‐of‐flight (ToF) is widely used to evaluate carrier mobilities in thick perovskite crystals and is often regarded as a direct probe of long‐range drift transport. Here we show that extracted ToF mobilities are sensitive to the electrode geometry. The concentration of electric field lines near electrode edges can dramatically shorten the transit time. ToF mobilities can be overestimated by up to 10 times by the distorted electric field in devices with electrode diameters smaller than the crystal thickness. An electrode‐diameter‐to‐crystal‐thickness ratio larger than 8 is required to obtain consistent charge transit time and thus the carrier mobility. Using a guard ring biased at the same potential as the electrode, the minimum electrode‐diameter‐to‐crystal‐thickness ratio can be reduced to 2.5.
Source: crossref · Quality: baseline
Research context
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Applied Physical Sciences University of North Carolina at Chapel Hill North Carolina USA
Department of Chemistry University of North Carolina at Chapel Hill North Carolina USA
Funding
National Institute of Biomedical Imaging and Bioengineering
References (31)
Show source-provided references
1. 10.1038/s41586‐022‐05268‐x10.1038/s41586‐022‐05268‐x ↗
2. 10.1002/adma.20230735710.1002/adma.202307357 ↗
3. 10.1002/adma.20240803610.1002/adma.202408036 ↗
4. 10.1002/adfm.20240118910.1002/adfm.202401189 ↗
5. 10.1038/s41586‐023‐05847‐610.1038/s41586‐023‐05847‐6 ↗
6. 10.1038/s41563‐025‐02310‐x10.1038/s41563‐025‐02310‐x ↗
7. 10.1039/D5CS00625B10.1039/D5CS00625B ↗
8. 10.1126/science.aaa576010.1126/science.aaa5760 ↗
9. 10.1063/1.494834410.1063/1.4948344 ↗
10. 10.1021/acsenergylett.7b0027610.1021/acsenergylett.7b00276 ↗
11. 10.1021/acs.jpcc.8b0034110.1021/acs.jpcc.8b00341 ↗
12. 10.1038/s41467‐019‐12513‐x10.1038/s41467‐019‐12513‐x ↗
13. 10.1038/s41467‐022‐31569‐w10.1038/s41467‐022‐31569‐w ↗
14. 10.1021/acsphotonics.4c0087310.1021/acsphotonics.4c00873 ↗
15. 10.1039/C6CS00942E10.1039/C6CS00942E ↗
16. 10.1002/adma.20160357310.1002/adma.201603573 ↗
17. 10.1021/acs.jpclett.5b0141910.1021/acs.jpclett.5b01419 ↗
18. 10.1039/C8EE03395A10.1039/C8EE03395A ↗
19. 10.1002/adfm.20221433910.1002/adfm.202214339 ↗
20. Halide Perovskites Single Crystals for X‐Ray Detection
21. 10.1021/acsphotonics.8b0087310.1021/acsphotonics.8b00873 ↗
22. 10.1126/sciadv.abb639310.1126/sciadv.abb6393 ↗
23. 10.1021/acs.jpcc.8b0351210.1021/acs.jpcc.8b03512 ↗
24. 10.1126/science.aaa272510.1126/science.aaa2725 ↗
25. 10.1088/1674‐1056/ac786410.1088/1674‐1056/ac7864 ↗
26. 10.1002/aelm.20230022610.1002/aelm.202300226 ↗
27. 10.1038/s41566‐023‐01154‐810.1038/s41566‐023‐01154‐8 ↗
28. M.Berger M.Inokuti H.Andersen et al. “Stopping Powers for Protons and Alpha Particles. ICRU Report 49. International Commission on Radiation Units and Measurements ”Bethesda MD (1993) https://www.nist.gov/publications/stopping‐powers‐protons‐and‐alpha‐particles.
29. Kamal A. · 201410.1007/978-3-642-38655-8 ↗
30. 10.1063/1.171036710.1063/1.1710367 ↗
31. 10.1038/nmat492710.1038/nmat4927 ↗