journal article·2026-07-27

An Open-Source Blender Add-On for Automated Design of Patient-Specific Splint Extensions for Condyle Positioning in Orthognathic Surgery: Workflow and Proof-of-Concept Validation

Sebastian Gubik, Anton Straub, Andreas Vollmer, Valentin Carl Steinacker, Cornelius Busse, Julian Manuel Volland, Niko Breitenbuecher, Urs Müller-Richter, Stefan Hartmann, Alexander Kübler, Roman C. Brands

Applied Sciences· Volume 16· Issue 15
Publisher page

Abstract

Background: Patient-specific splints have become an integral component of virtual surgical planning in orthognathic surgery. However, transferring the virtually planned condylar position into the intraoperative setting remains technically challenging and typically requires labor-intensive manual modification of splint geometries. The aim of this study was to develop and describe an open-source Blender add-on that automates the generation of patient-specific splint extensions for condyle positioning and to evaluate its technical feasibility in a proof-of-concept clinical setting. Methods: A Python-based add-on for the open-source 3D modelling software Blender was developed to automate the generation of condyle-positioning splint extensions from stereolithography (STL) models exported by a commercial virtual surgical planning system. The software architecture and processing pipeline comprise facilitated data import, coordinate normalization, extension generation, Boolean processing, optional manual refinement, and STL export for additive manufacturing. The workflow was applied in three patients undergoing bilateral sagittal split osteotomy. Postoperative correspondence between the planned and achieved mandibular positions was assessed using translational and rotational transformation parameters together with qualitative surface distance heatmaps provided by the planning software. Results: The proposed add-on successfully generated patient-specific splint extensions in all three proof-of-concept cases while automating manual modelling steps. All splints were successfully manufactured and applied intraoperatively without redesign. Postoperative evaluation demonstrated good agreement between the virtually planned and achieved mandibular positions, with only small translational and rotational deviations. Descriptive statistical analysis supported the technical feasibility and reproducibility of the proposed workflow. Conclusions: The presented open-source Blender add-on provides a reproducible and extensible workflow for automated generation of patient-specific condyle-positioning splint extensions. The proposed approach successfully integrates virtual surgical planning with additive manufacturing and demonstrates technical feasibility in a proof-of-concept clinical setting. The software establishes a foundation for future validation studies in larger patient cohorts and illustrates the potential of open-source tools to improve transparency, reproducibility, and accessibility in digital orthognathic surgery workflows.
Source: crossref · Quality: baseline

Research context

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, 97070 Würzburg, Germany

References (20)

Show source-provided references
1. Digital workflow for combined orthodontics and orthognathic surgery10.1016/j.coms.2019.08.004 ↗
2. 3D-guided face manipulation of 2D images for the prediction of postoperative outcome after cranio-maxillofacial surgery10.1109/TIP.2021.3096081 ↗
3. Effect of occlusal plane correction on lip cant in two-jaw orthognathic surgery: A three-dimensional analysis10.1016/j.jcms.2017.03.014 ↗
4. A meta-analysis and systematic review comparing the effectiveness of traditional and virtual surgical planning for orthognathic surgery: Based on randomized clinical trials10.1016/j.joms.2020.09.005 ↗
5. Comparison of two surgical techniques (HOO vs. BSSO) for mandibular osteotomies in orthognathic surgery—A 10-year retrospective study10.1007/s10006-022-01073-y ↗
6. Maintenance of the preoperative condyle position in orthognathic surgery10.1016/S1010-5182(97)80022-4 ↗
7. Clinical and radiographic evaluation of a computer-generated guiding device in bilateral sagittal split osteotomies
8. Evaluation of postoperative changes in condylar positions after orthognathic surgery using balanced orthognathic surgery system10.1186/s40902-022-00341-x ↗
9. Changes in the condylar head after orthognathic surgery in Class III patients: A retrospective three-dimensional study10.2319/052922-394.1 ↗
10. Faria-Teixeira, M.C., Azevedo-Coutinho, F., Serrano, Â.D., Yáñez-Vico, R.M., e Silva, F.S., Vaz-Carneiro, A., and Iglesias-Linares, A. (2025). Orthognathic surgery-related condylar resorption in patients with skeletal Class III malocclusion: A systematic review and meta-analysis. BMC Oral Health, 25.10.1186/s12903-024-04921-3 ↗
11. Bone microstructural characteristics or positional changes of the condyle affect short-term condylar resorption after orthognathic surgery10.1038/s41598-024-65077-2 ↗
12. Long-term evaluation of condylar positional and volumetric parameters and skeletal stability in Class III bimaxillary orthognathic surgery patients10.1016/j.ijom.2024.01.013 ↗
13. Intraoperative condylar positioning techniques on the mandible in orthognathic surgery10.1111/ocr.12568 ↗
14. Computer-assisted orthognathic surgery: Clinical evaluation of a mandibular condyle repositioning system10.1053/joms.2002.29069 ↗
15. Orthognathic positioning system: Intraoperative system to transfer virtual surgical plan to the operating field during orthognathic surgery10.1016/j.joms.2012.11.004 ↗
16. Computer-assisted orthognathic surgery: Feasibility study using multiple CAD/CAM surgical splints10.1016/j.oooo.2011.11.009 ↗
17. Changes in condylar long axis and skeletal stability after bilateral sagittal split ramus osteotomy with poly-L-lactic acid or titanium plate fixation10.1016/j.ijom.2005.02.013 ↗
18. A hypothesis on the desired postoperative position of the condyle in orthognathic surgery: A review10.1016/j.oooo.2011.12.026 ↗
19. Three-dimensional accuracy of navigation-guided bimaxillary orthognathic surgery: A systematic review and meta-analysis10.1016/j.jcms.2024.08.010 ↗
20. BGA: A noise-immune neural distillation framework for malicious signature extraction in high-entropy encrypted flows10.1016/j.ipm.2026.105040 ↗