journal article·2026-07-30

Computational models for predicting air permeability and thermal properties of polyester textile structures

Aušra Gadeikytė, Mindaugas Kurmis, Darius Drungilas, Rimantas Barauskas

Publisher page

Abstract

This study develops pore-scale computational models to predict air permeability and thermal properties of one-layer, two-layer, and three-dimensional polyester textile structures. Accurate prediction of airflow and heat transfer in multilayer textile structures is essential for evaluating the thermal insulation and ventilation characteristics of protective clothing while ensuring thermal comfort. Compared with previous studies, the proposed pore-scale models examine the combined effects of multilayer textile structure and additional ventilation on airflow and heat transfer. The models were created in COMSOL Multiphysics 6.2 using Navier-Stokes and Brinkman equations for airflow and the energy equation for heat transfer simulations in the laminar flow regime. The results showed that when the complexity of textile structures increased from one-layer to three-dimensional structures, the air permeability decreased from 1257.1 mm/s to approximately 447.9 mm/s, and the thermal resistance increased from 0.0144 to 0.123 m 2 K/W. Additional ventilation improved heat extraction, achieving an effective heat transfer coefficient of 53.64 W/m 2 K at a flow rate of 0.5 dm 3 /min and an inlet air temperature of 10°C. The numerical predictions showed good agreement with experimental data reported in the literature, confirming the applicability of the developed models for the analysis of airflow and thermal characteristics of multilayer textile structures.
Source: crossref · Quality: baseline

Affiliations

Department of Applied Informatics, Kaunas University of Technology, Kaunas, Lithuania

Klaipeda University, Klaipeda, Lithuania

Funding

Lithuanian Research Council and the Ministry of Education, Science, and Sports of the Republic of Lithuania

References (56)

Show source-provided references
1. 10.3390/su1503274710.3390/su15032747 ↗
2. 10.1080/00405000.2021.194394510.1080/00405000.2021.1943945 ↗
3. 10.3390/ma1516578610.3390/ma15165786 ↗
4. 10.3390/ma1515541710.3390/ma15155417 ↗
5. 10.1016/j.enbuild.2022.11220610.1016/j.enbuild.2022.112206 ↗
6. 10.1016/j.ijthermalsci.2020.10664410.1016/j.ijthermalsci.2020.106644 ↗
7. ISO 11092:2014(EN). Textiles — Physiological effects — Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test). https://www.iso.org/standard/65962.html (2014 accessed 7 September 2025).
8. 10.1177/0040517521102779910.1177/00405175211027799 ↗
9. 10.1016/B978-0-08-100453-1.00005-210.1016/B978-0-08-100453-1.00005-2 ↗
10. 10.1080/00405167.2021.195552410.1080/00405167.2021.1955524 ↗
11. ISO 9237:1995(en). Textiles — Determination of the permeability of fabrics to air. https://www.iso.org/obp/ui/en/#iso:std:iso:9237:ed-1:v1:en (accessed 20 December 2025).
12. 10.1016/B978-0-08-102609-0.00007-910.1016/B978-0-08-102609-0.00007-9 ↗
13. 10.1016/j.icheatmasstransfer.2025.10905310.1016/j.icheatmasstransfer.2025.109053 ↗
14. 10.1177/0040517524124591310.1177/00405175241245913 ↗
15. 10.2298/HEMIND240619012A10.2298/HEMIND240619012A ↗
16. 10.1515/aut-2023-003010.1515/aut-2023-0030 ↗
17. 10.1016/j.ijthermalsci.2018.01.02510.1016/j.ijthermalsci.2018.01.025 ↗
18. 10.1016/j.enbuild.2011.06.04010.1016/j.enbuild.2011.06.040 ↗
19. 10.1016/j.ijthermalsci.2025.11010510.1016/j.ijthermalsci.2025.110105 ↗
20. Barauskas R, Valasevičiūtė L, Jurevičiūtė A. Computational analysis and experimental investigation of heat and moisture transfer in multilayer textile package. Mat Sci (Medžiagotyra) 2009; 15(1): 80–85.
21. 10.1016/j.buildenv.2015.06.00810.1016/j.buildenv.2015.06.008 ↗
22. 10.3390/su14201346010.3390/su142013460 ↗
23. 10.1177/0040517524129334810.1177/00405175241293348 ↗
24. 10.35530/IT.071.04.165310.35530/IT.071.04.1653 ↗
25. 10.1080/00405000.2022.202760810.1080/00405000.2022.2027608 ↗
26. 10.1016/j.buildenv.2025.11311410.1016/j.buildenv.2025.113114 ↗
27. 10.1177/004051751142452910.1177/0040517511424529 ↗
28. 10.6092/polito/porto/259197310.6092/polito/porto/2591973 ↗
29. 10.1177/1528083724125361410.1177/15280837241253614 ↗
30. Zienkiewicz OC, Taylor RL, Nithiarasu P. The finite element method for fluid dynamics. 6th ed. Amsterdam: Elsevier, 2005.
31. 10.1201/978041587638410.1201/9780415876384 ↗
32. 10.1007/s11831-015-9143-210.1007/s11831-015-9143-2 ↗
33. 10.1177/004051751141497910.1177/0040517511414979 ↗
34. 10.1177/00219983920260080210.1177/002199839202600802 ↗
35. 10.1038/178824a010.1038/178824a0 ↗
36. 10.3390/ma1402040510.3390/ma14020405 ↗
37. 10.1016/j.ijmultiphaseflow.2020.10334910.1016/j.ijmultiphaseflow.2020.103349 ↗
38. Siddiqui MOR, Farooq S, Husain MD, et al. Prediction of air permeability and effective thermal conductivity of multifilament polyester yarn by finite element analysis. Polimery/Polymers 2023; 68: 6–18.
39. COMSOL. COMSOL Multiphysics Reference Manual. https://doc.comsol.com/6.4/docserver/#!/com.comsol.help.comsol/comsol_ref_mesh.24.24.html%23576386 (2025 accessed 21 December 2025).
40. 10.3390/ma1312288210.3390/ma13122882 ↗
41. 10.1016/j.commatsci.2013.04.00310.1016/j.commatsci.2013.04.003 ↗
42. 10.1533/978184569442510.1533/9781845694425 ↗
43. Militký J Křemenáková D. A simple methods for prediction of textile fabrics thermal conductivity. In: Meyer Josua P (ed.) 5th International conference on heat transfer fluid mechanics and thermodynamics. South Africa: Sun City 1–4 July 2007 pp. 1–5.
44. 10.1177/152808371773610410.1177/1528083717736104 ↗
45. 10.1177/002199831454519310.1177/0021998314545193 ↗
46. 10.1186/s40691-021-00276-310.1186/s40691-021-00276-3 ↗
47. 10.1177/004051751039246810.1177/0040517510392468 ↗
48. 10.3390/math1111253210.3390/math11112532 ↗
49. 10.3390/fluids604014010.3390/fluids6040140 ↗
50. 10.1007/978-94-009-0369-2_410.1007/978-94-009-0369-2_4 ↗
51. 10.1007/BFb010058310.1007/BFb0100583 ↗
52. 10.1177/152808371455144010.1177/1528083714551440 ↗
53. 10.1016/j.shaw.2022.11.00410.1016/j.shaw.2022.11.004 ↗
54. Sabantina L, Ehrmann A. New testing device for air permeability. Commun Dev Assem Text Prod 2023; 4: 164–170.
55. 10.1007/s00484-025-02907-610.1007/s00484-025-02907-6 ↗
56. 10.1007/s12221-021-9221-z10.1007/s12221-021-9221-z ↗