Influence of Heat Treatments on the Microstructure and Mechanical Properties of Two Fine Mg–Li–Y Alloy Wires for Bioresorbable Applications
Source abstract
Abstract
Two Mg–4Li–xY (x = 0.5 and 2.0 wt%) alloy wires are investigated for application in bioresorbable medical devices that experience high levels of plastic deformation. The two wires are supplied cold drawn to a diameter of 125 μm, and a series of thermal treatments are applied to maximize ductility. The ductility of the alloys is maximized soon after complete recrystallization. Prolonged annealing causes grain coarsening in the Mg–4Li–0.5Y alloy and precipitation of a Mg24Y5 phase in both alloys. Both wires are shown to achieve ≈20% elongation to failure in tension and survive high idealized bending strains (>40%). When heat treated for optimum mechanical properties for the intended application, the Mg–4Li–0.5Y alloy develops an intense transverse basal texture; however, this is shown to weaken with increased Y content in the Mg–4Li–2Y alloy wire. The increased Y content also prevents grain coarsening, indicating that the increased Y content restricts grain boundary mobility during annealing. Both alloys have relatively high ductility, meaning both are identified as promising new materials for application in bioresorbable medical devices that require to achieve and support high levels of plastic deformation during their life cycle.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical and Aerospace Engineering University of Strathclyde Glasgow G1 1XJ UK
Sorby Centre, Department of Materials Science and Engineering University of Sheffield Broad Lane Sheffield S3 7HQ UK
Funding
Henry Royce Institute
References (38)
Show source-provided references
1. 10.1002/adem.20110015210.1002/adem.201100152 ↗
2. 10.1016/j.actbio.2010.02.02810.1016/j.actbio.2010.02.028 ↗
3. 10.1016/j.actamat.2010.11.06410.1016/j.actamat.2010.11.064 ↗
4. 10.1016/j.pnsc.2014.08.01510.1016/j.pnsc.2014.08.015 ↗
5. 10.1002/adhm.20150018910.1002/adhm.201500189 ↗
6. 10.1016/S1003-6326(11)61581-110.1016/S1003-6326(11)61581-1 ↗
7. 10.1016/j.msea.2015.07.06910.1016/j.msea.2015.07.069 ↗
8. Chatterton M. · 2014 · 251
9. G.Chunlei L.Xiaohui N.Deng Z.Xiang Z.Kaihong H.Zhenghua inIOP Conf. Series: Materials Science and Engineering IOP Publishing Bristol UK2017 p.012051.10.1088/1757-899X/182/1/012051 ↗
10. 10.1002/adem.20200127810.1002/adem.202001278 ↗
11. 10.1002/jbm.b.3400810.1002/jbm.b.34008 ↗
12. 10.3389/fmats.2020.0019810.3389/fmats.2020.00198 ↗
13. 10.3390/met501000110.3390/met5010001 ↗
14. 10.1016/j.actbio.2009.09.01010.1016/j.actbio.2009.09.010 ↗
15. 10.1016/j.jmrt.2018.08.00310.1016/j.jmrt.2018.08.003 ↗
16. 10.1016/j.jma.2018.08.00110.1016/j.jma.2018.08.001 ↗
17. 10.3390/met1006077710.3390/met10060777 ↗
18. 10.1016/j.pmatsci.2017.10.00410.1016/j.pmatsci.2017.10.004 ↗
19. 10.1016/j.scriptamat.2021.11441410.1016/j.scriptamat.2021.114414 ↗
20. 10.1016/j.scriptamat.2017.05.01510.1016/j.scriptamat.2017.05.015 ↗
21. 10.1016/j.jallcom.2009.02.13110.1016/j.jallcom.2009.02.131 ↗
22. 10.1016/j.msec.2009.09.01410.1016/j.msec.2009.09.014 ↗
23. 10.1016/j.jma.2016.12.00210.1016/j.jma.2016.12.002 ↗
24. 10.1007/s11837-015-1366-z10.1007/s11837-015-1366-z ↗
25. 10.3390/ma1502056710.3390/ma15020567 ↗
26. 10.1016/j.msea.2012.09.01010.1016/j.msea.2012.09.010 ↗
27. 10.1016/j.scriptamat.2009.12.03310.1016/j.scriptamat.2009.12.033 ↗
28. 10.1016/j.actamat.2013.12.01510.1016/j.actamat.2013.12.015 ↗
29. 10.3390/ma1302042710.3390/ma13020427 ↗
30. 10.1007/s40843-018-9293-810.1007/s40843-018-9293-8 ↗
31. 10.1557/JMR.2008.041410.1557/JMR.2008.0414 ↗
32. 10.1016/j.msea.2017.05.11010.1016/j.msea.2017.05.110 ↗
33. 10.3390/ma1223392310.3390/ma12233923 ↗
34. BS ISO 7802:2013: · 2013
35. 10.1016/j.scriptamat.2017.11.00410.1016/j.scriptamat.2017.11.004 ↗
36. 10.1007/s11661-015-3199-310.1007/s11661-015-3199-3 ↗
37. 10.3390/met1009120810.3390/met10091208 ↗
38. 10.1016/S1359-6462(01)01212-X10.1016/S1359-6462(01)01212-X ↗