Soft Wearable Systems for Colorimetric and Electrochemical Analysis of Biofluids
Source abstract
Abstract
Abstract Wearable monitoring systems provide valuable insights about the state of wellness, performance, and progression of diseases. Although conventional wearable systems have been effective in measuring a few key biophysical markers, they offer limited insights into biochemical activity and are otherwise cumbersome in ambulatory modes of use, relying on wired connections, mechanical straps, and bulky electronics. Recent advances in skin‐interfaced microfluidics, stretchable/flexible electronics, and mechanics have created new wearable systems with capabilities in real‐time, noninvasive analysis of sweat biochemistry in combination with biophysical metrics. Here, the latest technologies in multifunctional sweat sensing systems are presented with a focus on novel microfluidic designs, fully‐integrated wireless electrochemical sensors, and hybrid biochemical/biophysical sensing capabilities, creating real‐time physiological insights.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Tactile and Sensory Interactions · Polydiacetylene-based materials and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Epicore Biosystems, Inc. Cambridge MA 02139 USA
Center for Bio‐Integrated Electronics Northwestern University Evanston IL 60208 USA
Department of Biomedical Engineering Northwestern University Evanston IL 60208 USA
School of Mechanical Engineering Kookmin University Seoul 02707 Republic of Korea
Department of Materials Science and Engineering Northwestern University Evanston IL 60208 USA
Funding
National Research Foundation of Korea
References (59)
Show source-provided references
1. 10.1021/acs.chemrev.8b0057310.1021/acs.chemrev.8b00573 ↗
2. 10.1109/JPROC.2019.290731710.1109/JPROC.2019.2907317 ↗
3. 10.1016/j.cobme.2019.01.00310.1016/j.cobme.2019.01.003 ↗
4. 10.1146/annurev-anchem-061417-12595610.1146/annurev-anchem-061417-125956 ↗
5. 10.1016/S0956-5663(01)00189-010.1016/S0956-5663(01)00189-0 ↗
6. 10.1039/C7LC00914C10.1039/C7LC00914C ↗
7. 10.1038/s41587-019-0040-310.1038/s41587-019-0040-3 ↗
8. 10.1038/s41587-019-0045-y10.1038/s41587-019-0045-y ↗
9. 10.1146/annurev-anchem-061318-11491010.1146/annurev-anchem-061318-114910 ↗
10. 10.1021/acs.chemrev.8b0071910.1021/acs.chemrev.8b00719 ↗
11. 10.1016/j.mtnano.2019.10004110.1016/j.mtnano.2019.100041 ↗
12. 10.1146/annurev-anchem-061318-11491010.1146/annurev-anchem-061318-114910 ↗
13. 10.1038/s41928-018-0043-y10.1038/s41928-018-0043-y ↗
14. 10.1126/sciadv.aar392110.1126/sciadv.aar3921 ↗
15. 10.1080/23328940.2019.163214510.1080/23328940.2019.1632145 ↗
16. 10.1063/1.492103910.1063/1.4921039 ↗
17. 10.1111/j.1469-445X.2000.02058.x10.1111/j.1469-445X.2000.02058.x ↗
18. 10.1038/nnano.2016.3810.1038/nnano.2016.38 ↗
19. 10.1126/sciadv.aar392110.1126/sciadv.aar3921 ↗
20. 10.1126/scitranslmed.aaf259310.1126/scitranslmed.aaf2593 ↗
21. 10.1002/adhm.20160135510.1002/adhm.201601355 ↗
22. 10.1021/acssensors.8b0121810.1021/acssensors.8b01218 ↗
23. 10.1039/C8LC00530C10.1039/C8LC00530C ↗
24. 10.1039/C7LC00525C10.1039/C7LC00525C ↗
25. 10.1002/smll.20170333410.1002/smll.201703334 ↗
26. 10.1126/sciadv.aau635610.1126/sciadv.aau6356 ↗
27. 10.1111/j.1600-0838.2010.01191.x10.1111/j.1600-0838.2010.01191.x ↗
28. 10.1123/ijsnem.18.5.45710.1123/ijsnem.18.5.457 ↗
29. 10.1002/smll.20170333410.1002/smll.201703334 ↗
30. 10.1016/j.coelec.2018.05.01410.1016/j.coelec.2018.05.014 ↗
31. 10.1038/nature1652110.1038/nature16521 ↗
32. 10.1109/TBME.2014.236999110.1109/TBME.2014.2369991 ↗
33. 10.1039/C8LC01082J10.1039/C8LC01082J ↗
34. 10.1002/advs.20180088010.1002/advs.201800880 ↗
35. 10.1002/smll.20180287610.1002/smll.201802876 ↗
36. 10.1021/acssensors.7b0096110.1021/acssensors.7b00961 ↗
37. 10.1126/sciadv.aav329410.1126/sciadv.aav3294 ↗
38. 10.1152/jappl.1967.22.1.7110.1152/jappl.1967.22.1.71 ↗
39. 10.1016/j.snb.2017.04.12910.1016/j.snb.2017.04.129 ↗
40. 10.1039/C7NR07225B10.1039/C7NR07225B ↗
41. 10.1038/s41598-018-33565-x10.1038/s41598-018-33565-x ↗
42. 10.1126/sciadv.160131410.1126/sciadv.1601314 ↗
43. 10.1016/j.talanta.2017.08.07710.1016/j.talanta.2017.08.077 ↗
44. 10.1126/sciadv.aar290410.1126/sciadv.aar2904 ↗
45. 10.1002/adfm.20180368410.1002/adfm.201803684 ↗
46. 10.1016/j.nanoen.2018.02.03310.1016/j.nanoen.2018.02.033 ↗
47. 10.1038/s41598-018-22746-310.1038/s41598-018-22746-3 ↗
48. 10.1002/adfm.20180638810.1002/adfm.201806388 ↗
49. 10.1002/adfm.20180504510.1002/adfm.201805045 ↗
50. 10.1038/s41551-019-0395-210.1038/s41551-019-0395-2 ↗
51. 10.1126/scitranslmed.aat843710.1126/scitranslmed.aat8437 ↗
52. 10.1126/scitranslmed.aan495010.1126/scitranslmed.aan4950 ↗
53. 10.1002/adfm.20180575410.1002/adfm.201805754 ↗
54. 10.1021/acssensors.7b0004710.1021/acssensors.7b00047 ↗
55. Rose D. P. · 2014
56. 10.1126/sciadv.aaw990610.1126/sciadv.aaw9906 ↗
57. MC10 Receives FDA 510(k) Clearance for the BioStamp nPoint™ System https://www.mc10inc.com/press‐media/fda‐510k‐clearance‐for‐the‐biostamp‐npoint‐system(accessed: October2019).
58. How wearable sweat trackers are providing athletes with critical hydration insights https://www.wareable.com/features/gatorade‐gx‐sweat‐patch‐vision‐7222(accessed: October2019).
59. L'Oréal Unveils Prototype Of First‐Ever Wearable Microfluidic Sensor To Measure Skin pH Levels https://www.prnewswire.com/news‐releases/loreal‐unveils‐prototype‐of‐first‐ever‐wearable‐microfluidic‐sensor‐to‐measure‐skin‐ph‐levels‐300773342.html(accessed: October2019).