A Highly Sensitive Hybrid Colorimetric and Fluorometric Molecular Probe for Cyanide Sensing Based on a Subphthalocyanine Dye
Source abstract
Abstract
Abstract A highly sensitive, selective colorimetric and fluorometric molecular probe based on a subphthalocyanine dye has been developed for cyanide‐anion determination in aqueous solution. It has also been shown that a carboxysubphthalocyanine derivative can be covalently anchored to transparent mesoporous nanocrystalline high‐surface‐area metal oxide films to detect low concentrations of cyanide anion in pure water with no interference from other anionic or cationic species.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Porphyrin and Phthalocyanine Chemistry · Molecular Sensors and Ion Detection · Luminescence and Fluorescent Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. 10.1021/cr960384510.1021/cr9603845 ↗
2. 10.1021/cr010421e10.1021/cr010421e ↗
3. 10.1002/1521-3757(20010202)113:3<502::AID-ANGE502>3.0.CO;2-A10.1002/1521-3757(20010202)113:3<502::AID-ANGE502>3.0.CO;2-A ↗
4. Guidelines establishing test procedures for the analysis of pollutants. EPA title 40CFR136 Appendix B: Definition and Procedure for the Determination of the Method Detection Limit (MDL).http://ecfr.gpoaccess.gov(last accessed 1st March 2006).
5. 10.1021/jo050528s10.1021/jo050528s ↗
6. 10.1021/ol047463k10.1021/ol047463k ↗
7. 10.1021/ol050747010.1021/ol0507470 ↗
8. 10.1039/B206500B10.1039/B206500B ↗
9. 10.1039/b501159k10.1039/b501159k ↗
10. 10.1021/cr010145410.1021/cr0101454 ↗
11. 10.1021/ja980508q10.1021/ja980508q ↗
12. 10.1039/a803533d10.1039/a803533d ↗
13. 10.1021/cr030206t10.1021/cr030206t ↗
14. 10.1021/jp045322u10.1021/jp045322u ↗
15. 10.1021/ol016902210.1021/ol0169022 ↗
16. 10.1021/ja039883v10.1021/ja039883v ↗
17. 10.1002/chem.20040077910.1002/chem.200400779 ↗
18. 10.1021/ja00182a03410.1021/ja00182a034 ↗
19. 10.1021/jo961018o10.1021/jo961018o ↗
20. 10.1039/B407860H10.1039/B407860H ↗
21. 10.1002/1521-3773(20020715)41:14<2561::AID-ANIE2561>3.0.CO;2-310.1002/1521-3773(20020715)41:14<2561::AID-ANIE2561>3.0.CO;2-3 ↗
22. 10.1002/ejoc.20030016910.1002/ejoc.200300169 ↗
23. Ring opening of the SubPc macrocycle in the presence of nucleophiles particularly water and alcohols has been previously observed: F. Diederich T. Torres unpublished results.
24. It is well known [6] that substitution of the halogen by an aryloxy axial ligand (or vice versa) in SubPc compounds only induces small if any changes in the color of the macrocycle. Therefore the mechanism described by Tian and co‐workers [5] to justify the behavior of their SubPc‐based fluoride sensor cannot be correct.
25. Several metals cataloged by the EPA as water contaminants have been tested including Hg2+ Cd2+ Cr3+ Zn2+ and Cu2+.
26. Fluorescence quantum yield of SubPc1in toluene solution is 0.4 according to the literature [8b].
27. 10.1039/b314138a10.1039/b314138a ↗
28. 10.1002/adfm.20030444410.1002/adfm.200304444 ↗