Morphological Origin of Charge Transport Anisotropy in Aligned Polythiophene Thin Films
Source abstract
Abstract
The morphological origin of anisotropic charge transport in uniaxially strain aligned poly(3‐hexylthiophene) (P3HT) films is investigated. The macroscale field effect mobility anisotropy is measured in an organic thin film transistor (OTFT) configuration and compared to the local aggregate P3HT mobility anisotropy determined using time‐resolved microwave conductivity (TRMC) measurements. The field effect mobility anisotropy in highly aligned P3HT films is substantially higher than the local mobility anisotropy in the aggregate P3HT. This difference is attributed to preferentially aligned polymer tie‐chains at grain boundaries that contribute to macroscale charge transport anisotropy but not the local anisotropy. The formation of sharp grains between oriented crystalline P3HT, through tie chain removal by thermal annealing the strained aligned films, results in an order of magnitude drop in the measured field effect mobility for charge transport parallel to the strain direction. The field effect mobility anisotropy is cut in half while the local mobility anisotropy remains relatively constant. The local mobility anisotropy is found to be surprisingly low in the aligned films, suggesting that the π−π stacking direction supports charge carrier mobility on the same order of magnitude as that in the intrachain direction, possibly due to poor intrachain mobility through chain torsion.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Organic Electronics and Photovoltaics · Conducting polymers and applications · Thin-Film Transistor Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical and Aerospace Engineering North Carolina State University Raleigh NC 27695 USA
Energy Sciences Division National Renewable Energy Laboratory Golden CO 80401 USA
Material Measurement Laboratory National Institute of Standards and Technology Gaithersburg MD 20899 USA
Physical Measurement Laboratory National Institute of Standards and Technology Gaithersburg MD 20899 USA
Stanford Synchrotron Radiation Lightsource Menlo Park CA 94025 USA
References (49)
Show source-provided references
1. 10.1002/adfm.20110090410.1002/adfm.201100904 ↗
2. 10.1021/nl303612z10.1021/nl303612z ↗
3. 10.1021/nn800574f10.1021/nn800574f ↗
4. 10.1063/1.12699110.1063/1.126991 ↗
5. 10.1038/nmat257010.1038/nmat2570 ↗
6. 10.1002/adfm.20100178110.1002/adfm.201001781 ↗
7. 10.1002/adma.20090154810.1002/adma.200901548 ↗
8. 10.1039/b510731h10.1039/b510731h ↗
9. 10.1016/S1369-7021(07)70016-010.1016/S1369-7021(07)70016-0 ↗
10. 10.1002/adma.20090093410.1002/adma.200900934 ↗
11. 10.1002/adfm.20110113910.1002/adfm.201101139 ↗
12. 10.1021/ma400516d10.1021/ma400516d ↗
13. 10.1126/science.109419610.1126/science.1094196 ↗
14. 10.1002/pssb.20104627810.1002/pssb.201046278 ↗
15. 10.1002/adma.20110428410.1002/adma.201104284 ↗
16. 10.1021/nl070022k10.1021/nl070022k ↗
17. 10.1063/1.471842410.1063/1.4718424 ↗
18. 10.1021/jp904841j10.1021/jp904841j ↗
19. 10.1103/PhysRevB.76.24520210.1103/PhysRevB.76.245202 ↗
20. 10.1002/adma.20080272210.1002/adma.200802722 ↗
21. 10.1063/1.282484510.1063/1.2824845 ↗
22. 10.1103/PhysRevB.71.16520210.1103/PhysRevB.71.165202 ↗
23. 10.1002/adma.20100176010.1002/adma.201001760 ↗
24. 10.1021/ja204515s10.1021/ja204515s ↗
25. 10.1103/PhysRevB.86.20520510.1103/PhysRevB.86.205205 ↗
26. 10.1021/la061897210.1021/la0618972 ↗
27. 10.1063/1.191476810.1063/1.1914768 ↗
28. 10.1103/PhysRevLett.98.20640610.1103/PhysRevLett.98.206406 ↗
29. 10.1063/1.311090410.1063/1.3110904 ↗
30. 10.1063/1.306526710.1063/1.3065267 ↗
31. 10.1080/1532179050047119410.1080/15321790500471194 ↗
32. 10.1021/ja055192i10.1021/ja055192i ↗
33. 10.1063/1.276978210.1063/1.2769782 ↗
34. 10.1021/jp806149310.1021/jp8061493 ↗
35. 10.1002/adma.20080096310.1002/adma.200800963 ↗
36. 10.1016/S0301-0104(98)00037-810.1016/S0301-0104(98)00037-8 ↗
37. 10.1002/polb.2237910.1002/polb.22379 ↗
38. 10.1021/jp021773810.1021/jp0217738 ↗
39. 10.1021/jp711341210.1021/jp7113412 ↗
40. 10.1016/0301-0104(82)85148-310.1016/0301-0104(82)85148-3 ↗
41. 10.1016/0379-6779(96)80202-510.1016/0379-6779(96)80202-5 ↗
42. 10.1063/1.165982710.1063/1.1659827 ↗
43. 10.1016/S0032-3861(00)00487-010.1016/S0032-3861(00)00487-0 ↗
44. 10.1021/jz201229a10.1021/jz201229a ↗
45. 10.1002/1521-4095(200111)13:21<1627::AID-ADMA1627>3.0.CO;2-U10.1002/1521-4095(200111)13:21<1627::AID-ADMA1627>3.0.CO;2-U ↗
46. 10.1002/adfm.20090227310.1002/adfm.200902273 ↗
47. 10.1021/jz401142e10.1021/jz401142e ↗
48. 10.1021/jz401711m10.1021/jz401711m ↗
49. Certain commercial equipment or materials are identified in this paper in order to specify the experimental procedure adequately. Such identification is not intended to imply recommendation or endorsement by the National Institute of Standards and Technology nor is it intended to imply that the materials or equipment identified are necessarily the best available for the purpose.