Microwave Hyperthermia Technology Based on Near‐Field Focused Metasurfaces: Design and Implementation
Source abstract
Abstract
Abstract This paper presents a near‐field focused metasurface design method for microwave hyperthermia. Utilizing full‐wave electromagnetic simulation, a novel dual‐layer metasurface unit with the following characteristics is developed: transmission efficiency higher than −1 dB, adjustable transmission phase from 0° to 360°, and insensitivity to the polarization and incident angle of the incoming wave. Leveraging phase compensation theory, the units at different positions in the array to achieve near‐field focusing functionality is meticulously designed. To further optimize transmission efficiency, the transmission phase of the central unit of the metasurface to 76° is tuned. When applying this near‐field focused metasurface to microwave hyperthermia, the electromagnetic and thermal effects in biological tissues is conducted simulations and experiments to analyzed. The results demonstrate that the proposed metasurface can effectively focus microwave energy, achieving efficient microwave transmission in pork tissue and generating localized high temperatures in the target area. This research introduces new design concepts and implementation strategies for the development of microwave hyperthermia technology.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Energy Harvesting in Wireless Networks · Antenna Design and Analysis · Metamaterials and Metasurfaces Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Power Transmission Equipment Technology School of Electrical Engineering Chongqing University Chongqing 40044 China
School of Microelectronics and Communication Engineering Chongqing University Chongqing 400044 China
School of Science Jiangnan University Wuxi 214122 China
Funding
Fundamental Research Funds for the Central Universities
References (28)
Show source-provided references
1. 10.1016/S0360-3016(97)00731-110.1016/S0360-3016(97)00731-1 ↗
2. 10.1080/0265673050033186810.1080/02656730500331868 ↗
3. 10.1016/j.biomaterials.2017.12.01210.1016/j.biomaterials.2017.12.012 ↗
4. 10.1002/smll.20180326210.1002/smll.201803262 ↗
5. 10.1016/j.addr.2020.03.00410.1016/j.addr.2020.03.004 ↗
6. 10.3390/pharmaceutics1502048710.3390/pharmaceutics15020487 ↗
7. 10.1016/j.biomaterials.2014.12.03510.1016/j.biomaterials.2014.12.035 ↗
8. 10.1109/TBME.2009.202526410.1109/TBME.2009.2025264 ↗
9. 10.1109/TBME.2015.241367210.1109/TBME.2015.2413672 ↗
10. 10.1016/j.ijheatmasstransfer.2015.06.03010.1016/j.ijheatmasstransfer.2015.06.030 ↗
11. 10.3390/electronics903053510.3390/electronics9030535 ↗
12. 10.23919/EuMC.2017.823098210.23919/EuMC.2017.8230982 ↗
13. 10.5370/JEET.2016.11.6.174410.5370/JEET.2016.11.6.1744 ↗
14. 10.1002/mop.3303910.1002/mop.33039 ↗
15. M. R. S.Ramu K.Arunachalam inMicrostrip C Patch Antenna for Hyperthermia Treatment: A Comparative Numerical Study with Cavity Backed C Patch Antennas[C] 2022 3rd URSI Atlantic and Asia Pacific Radio Science Meeting (AT‐AP‐RASC) IEEE 2022 pp.1–4.10.23919/AT-AP-RASC54737.2022.9814180 ↗
16. 10.1109/TAP.2018.279438510.1109/TAP.2018.2794385 ↗
17. 10.1080/09205071.2016.120756810.1080/09205071.2016.1207568 ↗
18. Deng J.‐H. · IEEE Sens. J. · 2023
19. 10.1021/acsaelm.3c0157810.1021/acsaelm.3c01578 ↗
20. 10.1016/j.ceramint.2024.04.08510.1016/j.ceramint.2024.04.085 ↗
21. 10.1016/j.applthermaleng.2023.12107410.1016/j.applthermaleng.2023.121074 ↗
22. 10.1109/TAP.2022.321069110.1109/TAP.2022.3210691 ↗
23. 10.1016/j.rinp.2023.10715910.1016/j.rinp.2023.107159 ↗
24. 10.1109/TAP.2016.264283210.1109/TAP.2016.2642832 ↗
25. 10.1002/adom.20170007910.1002/adom.201700079 ↗
26. 10.1016/j.sna.2023.11497210.1016/j.sna.2023.114972 ↗
27. https://www.icellbioscience.com/news/NewsContent/824.
28. 10.1109/JERM.2021.305308210.1109/JERM.2021.3053082 ↗