Alignment‐Free Liquid‐Capsule Pressure Sensor for Cardiovascular Monitoring
Source abstract
Abstract
Abstract Wearable pressure sensors enable long‐term real‐time health monitoring in a noninvasive and power‐efficient way; however, the sensors are often required to be precisely applied at the optimal measurement spot, e.g., nearby radial artery, for signal acquisition, causing inconvenience for untrained users or the elders. In this paper, a wearable liquid‐capsule sensor platform embedded with a piezo‐resistive pressure sensor is presented for continuous, accurate, and alignment‐relaxed physiological monitoring, i.e., heart rate (HR) and blood pressure (BP) tracking. The flexible capsule design ensures comfort and good device conformation to any skin regions. For HR and BP measurements, experiments are performed on 12 human subjects. The results show that the capsuled sensor can continuously track: 1) HR with a mean absolute difference (MAD) of 0.88 beats per minute (bpm) and 2) BP with a MAD<3 mmHg for both diastolic and systolic blood pressure. The new liquid‐capsule‐based sensor platform may help to realize an accurate, flexible, robust, and low‐power solution for next‐generation wearable health monitoring devices.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Non-Invasive Vital Sign Monitoring · Muscle activation and electromyography studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical and Automation Engineering The Chinese University of Hong Kong Shatin N.T. Hong Kong
Department of Electronic Engineering The Chinese University of Hong Kong Shatin N.T. Hong Kong
Funding
Innovation and Technology Commission - Hong Kong · Research Grants Council, University Grants Committee
References (37)
Show source-provided references
1. 10.1001/jama.1979.0329045003302010.1001/jama.1979.03290450033020 ↗
2. 10.1016/0002-8703(87)90666-110.1016/0002-8703(87)90666-1 ↗
3. 10.1016/S0140-6736(97)11144-810.1016/S0140-6736(97)11144-8 ↗
4. 10.1038/sj.jhh.100152910.1038/sj.jhh.1001529 ↗
5. 10.1016/0140-6736(90)90878-910.1016/0140-6736(90)90878-9 ↗
6. 10.1001/jama.1996.0353044005103610.1001/jama.1996.03530440051036 ↗
7. 10.1146/annurev-bioeng-071811-15001810.1146/annurev-bioeng-071811-150018 ↗
8. 10.1016/j.tibtech.2014.04.00510.1016/j.tibtech.2014.04.005 ↗
9. 10.1126/science.120615710.1126/science.1206157 ↗
10. 10.1109/JBHI.2016.262099510.1109/JBHI.2016.2620995 ↗
11. 10.1002/adma.20140380710.1002/adma.201403807 ↗
12. 10.1021/nn500441k10.1021/nn500441k ↗
13. 10.1038/ncomms400210.1038/ncomms4002 ↗
14. 10.1002/adma.20130518210.1002/adma.201305182 ↗
15. 10.1109/LED.2017.278453810.1109/LED.2017.2784538 ↗
16. 10.1038/ncomms674710.1038/ncomms6747 ↗
17. 10.1002/adfm.20160528610.1002/adfm.201605286 ↗
18. 10.1002/adma.20170097510.1002/adma.201700975 ↗
19. 10.1002/adma.20160620610.1002/adma.201606206 ↗
20. 10.1002/adfm.20150456010.1002/adfm.201504560 ↗
21. 10.1021/acssensors.7b0023010.1021/acssensors.7b00230 ↗
22. 10.1038/ncomms283210.1038/ncomms2832 ↗
23. 10.1002/admt.20170022210.1002/admt.201700222 ↗
24. 10.1002/adma.20170198510.1002/adma.201701985 ↗
25. 10.1038/srep1463710.1038/srep14637 ↗
26. 10.1038/ncomms413210.1038/ncomms4132 ↗
27. 10.1097/00004872-199816121-0003310.1097/00004872-199816121-00033 ↗
28. Mcveigh G. E. · Clin. Sci. · 2001 · 100 · 38710.1042/cs1000387 ↗
29. 10.1016/0002-9343(93)90313-E10.1016/0002-9343(93)90313-E ↗
30. 10.1002/adma.20150253510.1002/adma.201502535 ↗
31. 10.1038/s41598-017-11507-310.1038/s41598-017-11507-3 ↗
32. 10.1007/s00542-016-2895-210.1007/s00542-016-2895-2 ↗
33. 10.1109/TBME.2007.91068110.1109/TBME.2007.910681 ↗
34. 10.1002/adfm.20140037910.1002/adfm.201400379 ↗
35. 10.1111/j.1469-8986.1981.tb01545.x10.1111/j.1469-8986.1981.tb01545.x ↗
36. 10.1007/BF0234575510.1007/BF02345755 ↗
37. Poon C. · 2006